How to take measures for errors
Condition
Although the
slide controller is
placed on
"Strong ", motor
doesn't operate.
Although the
motor operates
normally, the
chemical isn't
sprayed
Although the
motor operates
normally, the
chemical is
sprayed
intermittently.
Measures for errors and maintenance
Check whether the power cord of the product is plugged at the
outlet.
Check whether the power cord jack and power cord of the
product are connected.
Check whether the power
Check the fuse at the bottom of the nebulizer *
Check whether the chemical bottle is normally placed on the
body.
Check whether the control valve of the chemical bottle is
closed.
Check whether the cap of the chemical bottle is closed
completely.
Check whether the chemical bottle is damage. (if so, it is
necessary to buy the chemical bottle.)
Check whether the O-ring of connector to connect the body
and the chemical bottle is damage, (if so, its rating: internal
diameter: 7.5 and external diameter: 10.5)
Check whether the nozzle cap for cleaning with big hole size is
place and then replace it with one with small hole size.
After releasing the chemical bottle, insert the air of 1Kg/m
the left hole of the connector in the body and remove the
foreign matters within it.
After releasing the body of the product and its solenoid valve,
clean it and reassemble.
(Refer to the manual for solenoid valve Assistance).
Check whether the chemical bottle is normally placed on the
body
Check whether the control valve of the chemical bottle is
closed.
Check whether the cap of the chemical bottle is closed
completely.
Check whether the chemical bottle is damage. (if so, it is
necessary to buy the chemical bottle)
After releasing the chemical bottle, insert the air of 1Kg/m
the left hole of the connector in the body and remove the
foreign matters within it.
After releasing the body of the product and its solenoid valve,
clean it and reassemble. (Refer to the manual for Solenoid
valve A/S)
After realising the body of the product, check whether the pipe
is connected normally and reassemble it again.
Check whether the pipe hose within the product is damage, if
so, replace if with another.
Measures
4
EN
Remark
If there are still
errors after taking
measures, request
A/S.
* Use the fuse with
the proper capacity
in replacing fuses.
(250V/10A)
- For the nozzle cap
with big hole size
(diameter 35), it is
used for air
cleaning.
If there are still
errors after taking
measures, request
Assistance.
2
into
If there are still
2
into
errors after taking
measures request
Assistance.