EN
5.2.5
DOSE COUNTS
When starting the machine, keep pressed for 5 seconds the grinding start button (6) and
then select one of the counts:
• Single dose button (14)
• Double dose button (15)
• Single dose button (14)
of the dispensed continuous doses;
On the display, only the selected buttons remain on and the numbers of doses are
shown in pairs progressively.
For instance, if the dose total is 142536, the display shows the digits 14, 25, and 36
(each one for two seconds).
After the last digit pair, it stops for 4 seconds and then the sequence restarts.
To exit the count, press the grinding start button (6).
5.2.6
DISPLAY CONTRAST ADJUSTMENT
When starting the machine, keep pressed the grinding start button (6) and then press
the button (12)
only the buttons (12)
grinding start button (6).
5.3
MANUAL MODE FUNCTION
• Lay the filter holder on the fork (7)(Fig.7).
• Push the filter holder until in contact with the micro-switch button (6) so to dispense
the ground coffee from the spout (5).
• The dispensing stops moving away the filter holder from the microswitch (6).
5.4
GRINDING SETTING
Turn the adjustment knob (8) clockwise for more finely ground coffee and counter-
clockwise for a coarser grind. The adjustment is to be made gradually, by grinding a little
coffee every max 2 notches.
If the knob is turned of a turn with the motor in standstill, the machine could stop.
5.5
FILTER HOLDER FORK ADJUSTMENT
• Insert the filter holder fork (7) (Fig. 6) into its seat.
• With a screwdriver, loosen the fixing screw of the filter holder fork (7). Do not loosen
ME041-5-5A-A0-R00_MANUALE ISTRUZIONI MIGNON XL IT-EN-DE-FR-ES.indb 131
ME041-5-5A-A0-R00_MANUALE ISTRUZIONI MIGNON XL IT-EN-DE-FR-ES.indb 131
: access to the count of the dispensed single doses;
: access to the count of the dispensed double doses;
and double dose button (15)
or (13)
to access the contrast adjustment. On the display,
and (13)
To exit the contrast adjustment, press the
: access to the count
31
03/12/2020 15:50:22
03/12/2020 15:50:22