Type 2103, 2104, 2105
Replacement for control functions B and I
→
Clamp the valve body in a holding product.
(applies only to valves not yet installed).
→
Loosen the four body screws.
→
Remove the actuator from the body.
→
Unbutton or unscrew old diaphragm. If attachment is with a
bayonet catch, remove the diaphragm by rotating it through 90°.
→
Install new diaphragm.
→
Align diaphragm.
The marker flap of the diaphragm must be perpendicular to
the direction of flow (see "Fig. 40")!
→
Place actuator back on the body.
→
Lightly cross-tighten the body screws without pressurization until
the diaphragm is between the body and actuator.
Do not tighten screws yet.
→
Pressurize pilot air port 1 of the actuator with compressed air
(5 bar) (see "Fig. 40").
→
Actuate the diaphragm valve twice.
→
Tighten the body screws to the permitted tightening torque (see
"Tab. 16: Tightening torques for diaphragms").
Repairs
Orifice DN
Tightening torques for diaphragms [Nm]
(diaphragm
EPDM/FKM
size) [mm]
8
2.5
15
3.5
20
4
25
5
40
8
50
12
Tab. 16: Tightening torques for diaphragms
english
PTFE / advanced PTFE /
laminated advanced PTFE
2.5
4
4.5
6
10
15
39