Antari W-515D Mode D'emploi page 10

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

DMX512 Settings
Channel A
0 - 5 = off (no output)
6 - 255 = output volume control (1 - 100 % output)
Both models are equipped with a DMX512 system. For connecting a DMX controller,
3-pin and 5-pin male-female XLR connections are provided at the back of each
machine. The machines uses one control channel for adjusting the output volume.
The channel has a DMX value range of 0 to 255. After connecting a DMX controller,
timer functions such as output
the DMX controller or the DMX control software. The machine cannot be controlled
via the built-in control panel nor the W-1 wireless remote anymore. By using the
DMX protocol, fog machines, lighting effects, and other special effects machines
can be interconnected and easily controlled.
If channel A has a value from 0 to 5, the unit is off.
Between the values 6 to 255 the fog output volume is regulated. With
6 being the minimum output volume and 255 approaching the maximum
output volume.The output volume rises as the DMX value is increased.
Note: If, for example, the machine is assigned to the DMX address 124, channel A
corresponds to DMX address 124.
Note
If you experience low output, pump noise or no output at all, unplug immediately.
Check the fluid level, the external fuse, the connection to the remote control, and
power from the wall. If all of the above appears to be O.K., plug the unit
If fog does not come out after holding the remote button down for 30 seconds,
check the hose attached to the tank to make sure there is fluid going through the
hose. If you are unable to determine the cause of the problem, do not simply
continue pushing the remote button, as this may damage the unit. Return the
machine to your Antari dealer.
Pin
1
2
3
4
5
duration and interval can be programmed using
Function
Ground
Data-
Data+
N/A
N/A
in
again.