SETTING UP
After laying and connecting all the cables mentioned above, have skilled staff commission the operator by fi rst running the
following functions:
- type of motor (A1);
- number of motors (F46);
- motors test (A2)
Self-learning of the gate travel (A3).
Motor type
The control board is not confi gured to control the gearmotors. You will need to confi gure it by setting function A1 as follows:
Select A1.
Press ENTER to confi rm.
Select 5 and press ENTER to confi rm the confi guration.
Number of motors
The control board is confi gured to control two gearmotors. To control just one gearmotor, set function F46 as follows:
Select F46.
Press ENTER to confi rm.
Select 1 and press ENTER to confi rm the confi guration for just
one gearmotor.
a
I
5
F
4
6
i