After an opening command, the M1 gearmotor starts after the M2 gearmotor. The delay time is adjustable between 0 and 10 seconds.
F24 Delayed closing time
After either a closing command or an automatic closing, the M2 gearmotor starts after gearmotor M1. The delay time can be set to between
0 and 25 seconds.
F25
Do not modify. Function unavailable.
F26 Ramming thrust time
After an opening or closing command, the gearmotors thrust inward for an adjustable time between one and two seconds.
F27 Lock time
After an opening or closing command, the electric lock releases for an adjustable time between one and four seconds.
F28 Maneuvering speed of gearmotor M1
Setting the opening and closing speeds of gearmotor M1, calculated as a percentage.
F29 Maneuvering speed of gearmotor M2
Setting the opening and closing speeds of gearmotor M2, calculated as a percentage.
F30 Slow-down speed of gearmotor M1
Setting the opening and closing slow-down speed of gearmotor M1, calculated as a percentage.
F31 Slow-down speed of gearmotor M2
Setting the opening and closing slow-down speed of gearmotor M2, calculated as a percentage.
F32
Do not modify. Function unavailable.
F33 Self-learning speed
Setting the gearmotor speed during the self-learning phase, calculated as a percentage.
F34 Boom travel sensitivity
Adjusting obstruction detection sensitivity during boom travel.
F35 Slow-down sensitivity
Adjusting obstruction detection sensitivity during slow-down.
F36 Adjusting partial opening
Percentage adjustment on total gate travel, of the M2 opening.
0=0 seconds /... / 5=5 seconds (default) /... / 25=25 seconds.
1= 1 second (default) / 2= 2 seconds
1= 1 second (default) / 4= 4 seconds
40= Minimum speed /... / 100= Maximum speed (default)
40= Minimum speed /... / 100= Maximum speed (default)
20= Minimum speed /... / 50= Speed (default) /... / 60= Maximum speed
20= Minimum speed /... / 50= Speed (default) /... / 60= Maximum speed
30= Minimum speed /... / 50= Speed (default) /... / 60= Maximum speed
10= Maximum sensitivity /... / 100= Minimum sensitivity (default)
10= maximum sensitivity /... / 100= minimum sensitivity (default)
10= 10% of gate travel (default) /... / 80= 80% of gate travel