F11 Encoder
Managing slow-downs, obstruction detections and sensitivity.
F12 Slowed-down departure
With each opening and closing command, the gate starts moving slowly for a few seconds.
F 13 Closing thrust
At the closing limit switch, the gearmotors make the leaves perform a brief closing thrust.
F14
Do not modify. Function unavailable.
F16 Ramming
Before every opening or closing maneuver, the leaves thrust inwards to release the electric lock. The thrust time, is set with F 26.
F17 Lock
Releasing the electric lock with opening and closing gate-leave thrust. The intervention time is set up with F27.
F18
Do not modify. Function unavailable.
F19 Automatic closing time
The automatic-closing wait starts when the opening limit switch point is reached and can be set to between 1 and 180 seconds. The automatic
closing does not activate if any of the safety devices trigger when an obstruction is detected, or after a total stop, or during a power outage.
F20 Automatic closing time after pedestrian or
partial openings
Theautomatic-closing wait starts when the opening limit switch point is reached and can be set to between 1 and 180 seconds. The automatic
closing does not activate if any of the safety devices trigger when an obstruction is detected, or after a total stop, or during a power outage.
F21 Prefl ashing time
Adjusting the pre-fl ashing time for the fl ashing light connected to 10-E before each maneuver. The fl ashing time is adjustable from one to ten
seconds.
F22 Working time
Motors working time, when opening and closing. Adjustable between fi ve and 180 seconds.
F23 Delayed opening time
0 =Activated (default) / 1 = Deactivated
0= Deactivated (default) / 1= Activated
0 =Deactivated (default) /1= Minimum thrust / 2=Average thrust / 3= Maximum thrust
1= Deactivated (default)
0= Deactivated (default) / 1= Activated
0= With opening command (default) / 1= With closing command / 2= with both
commands
0= Deactivated (default)
0= Deactivated (default) / 1=1 second /... / 180=180 seconds
0= Deactivated (default) / 1=1 second /... / 180=180 seconds
0= Deactivated (default) / 1=1 second /... / 10= 10 seconds
5= 5 seconds /... / 120=120 seconds (default)
0=0 seconds /... / 2=2 seconds (default) /... / 10= 10 seconds.