Suggested Confi gurations
LX2 Series
Side wall outlets using LDK3
Note - Vertical 6-5/8" venting straight
off the 2200J with no offset may conflict
with forward facing plenum. Offset vent
around plenum. If using 8" vertical venting,
a 20" deep cavity will not accomodate the
plenum. Adjust cavity depth accordingly.
Front wall outlet using LDK1 or LDK4
4
Not to scale
H Series corner installations
Note - Vertical venting straight off the H6
heater will clear plenum without having
to offset venting. H5 heaters will require
venting to offset around plenum.
Note - LDK Plenum may require larger
minimum corner cavity than heater
minimum corner cavity - plan accordingly!
WARNING
!
This duct kit is approved for horizontal
discharge ONLY. DO NOT install plenum in
floor or ceiling. DO NOT COVER OR PLACE
objects in front of air outlet(s). AVOID
locating outlet within 7 feet of the floor level
as discharge air temperatures are hot!
D O N O T D I S C H A R G E T H R O U G H
E X T E R I O R W A L L S !
NOTE This duct kit may also be used for
outdoor installations (except 2200J) where
reduced wall surface temperatures above the
unit are desired. The discharge grills must
be located under the weatherproof enclosure
described in the GV60CKO Outdoor Fireplace
Conversion Kit instructions.