Suggested Confi gurations
Linear Series
Front wall outlet using LDK1 or LDK4
Rear wall outlet using LDK1 or LDK4
Note: Fireplace vent may confl ict with plenum.
Off set vent around plenum.
Side wall outlets using LDK3
Rear wall outlets using LDK3
Note - Vertical venting straight off
the 1600J heater will NOT clear the
38" (LDK4) or 48" (LDK1) plenums
without offsetting the vent around
the plenum.
1600J L1 2-sided using LDK1 or LDK4
Not to scale
Note -
Take-off collars
are staggered,
two per side
Centerline of heater and plenum
C L
Linear* corner installations with front or rear wall
outlet using LDK1, LDK3 or LDK4 (*except 1600J)
WARNING
!
This duct kit is approved for horizontal
discharge ONLY. DO NOT install plenum in
floor or ceiling. DO NOT COVER OR PLACE
objects in front of air outlet(s). AVOID
locating outlet within 7 feet of the floor level
as discharge air temperatures are hot!
D O N O T D I S C H A R G E T H R O U G H
E X T E R I O R W A L L S !
NOTE This duct kit may also be used for
outdoor installations (except 2200J) where
reduced wall surface temperatures above the
unit are desired. The discharge grills must
be located under the weatherproof enclosure
described in the GV60CKO Outdoor Fireplace
Conversion Kit instructions.
3