SYMPTOM
Smoke enters the room
during start-up.
Smoke enters the room
while re-loading.
NOTE: Open doors slow-
ly to allow pressures to
balance before opening
doors completely.
Appliance smoking.
46
W415-1676 / D / 03.02.20
PROBLEM
Damper in closed position.
Cold air blockage in chimney
Close the doors.
Damper in closed position
Insuffi cient draft.
Damper in closed position
Chimney cold
Inadequate supply of combus-
tion air
The outside air damper
opened.
The smoke passage is blocked
in the appliance or chimney.
The smoke fl ow impeded by
too long of a horizontal pipe or
too many bends.
A weak draft perhaps caused
by a leaky chimney, a cold out-
side chimney, too short a chim-
ney, or a chimney too close to a
tree or a higher roof.
TEST SOLUTION
-
Open damper.
-
Burn a piece of newspaper to establish a draft.
-
Open outside air control damper.
-
Open damper.
-
Chimney height and outside conditions can negatively
affect draft. In these cases a small amount of smoke may
enter the home. Adding more pipe or a draft-inducing cap
may help.
-
Clean chimney
-
Open damper.
-
Burn a piece of paper to establish a draft, fuel as
necessary to establish a hot fl ame.
-
Chimney height and outside conditions can negatively
affect draft. In these cases a small amount of smoke may
enter the home. Adding more pipe or a draft-inducing cap
may help.
-
Close damper.
-
Check chimney for blockage and clear if necessary.
-
Refer to "typical chimney installation" section for proper
chimney bends.
-
Chimney height and outside conditions can negatively
affect draft. In these cases a small amount of smoke may
enter the home. Adding more pipe or a draft-inducing cap
may help. Refer to "typical chimney installation" section for
proper chimney bends.