operation and adjustments
EN
6.6
fi rebrick installation
WARNING
!
•
Risk of fi re! Operation of the appliance without the fi rebricks can result in excessive temperatures that will
damage the appliance, chimney and the surrounding enclosure.
note:
Ensure fi bre panels set in behind brick are in good condition before installing fi rebrick. If fi bre panels need to
be replaced, hold panels in position or secure with masking tape until fi rebrick is installed.
Proper Installation of Side Panels:
Side panels will have two distinct angles on either side of each panel. The shallow angle should face the outside of the
appliance. The steeper angle should face to the inside of the appliance and will match to the adjacent panel.
A.
Tilt and install the right rear
fi rebrick against the wall.
D.
Tilt the top right fi rebrick
and secure under the
retaining bracket.
32
W415-1676 / D / 03.02.20
B.
Install the middle and left
rear fi rebricks.
E.
Install the remaining top fi rebricks,
securing under the retaining
brackets. Install the andirons into the
bottom fi rebricks.
C.
Install the bottom
fi rebricks to aid securing
the rear fi rebricks against
the wall.