10. Error diagnosis

Onl�� the green LED ma�� illuminate i� the suppl�� voltage has been correctl�� connected. I� one o� the red LEDs 
illuminate, there is an error in the s��stem which can be pinpointed with the aid o� the LED.
LED
LEDs are not 
The suppl�� voltage is missing, too 
illuminated
low or has been connected incor-
rectl��
A single red LED 
Contact edge(s) not connected, 
is illuminated
connected incorrectl�� or �ault��
One o� the contact edge connections 
is not being used
Both o� the red 
The transmission line is �ault�� or has 
Transmit LEDs 
been installed incorrectl��
are illuminated
Contact edge(s) not connected, 
connected incorrectl�� or �ault��
*  I� the error is not in the wiring, the �unction o� the electronics can be tested b�� connecting an 8.2 kΩ 
resistor to all SCE inputs on the  ISK 71‑242 (ISK 71‑942) electronic evaluation s��stem (terminals 3, 10
and terminals 3, 11) and to the travelling coil core (connections O and C). I� the electronics work per�ectl�� 
after per�orming the test, the sa�et�� contact edges must be checked using an ohmmeter. To do this, the 
respective connection on the SCE �or the electronic evaluation s��stem or �or the travelling coil core must 
be disconnected and connected to an ohmmeter.
 
The resistance must be 8.2 kΩ ±500 Ω when the sa�et�� contact edge is inactive and must not exceed 500 Ω 
when it is active.
**  I� both o� the LEDs �or the travelling SCEs (Transmit Opening and Transmit Closing) illuminate, there is 
an error in the inductive signal transmission s��stem. The most �requent causes o� these errors are bad 
coil core connections, incorrectl�� installed cable s��stem components (see IKS sa�et�� transmission s��stem 
assembl�� instructions) or an impermissibl�� low suppl�� voltage.
 
The  maximum  resistance  value  o�  the  cable  loop  must  not  exceed  3 Ω  .  The  resistance  value  can  be 
measured b�� disconnecting the steel cable �rom the ground terminal and then measuring the resistance 
between the end o� the steel cable and ground terminal.
Error
Check connections and suppl�� voltage:
‑  24 V AC/DC at terminals 8 9
Tolerance range: ±10%
- Check the connections o� the corresponding 
‑  Check sa�et�� contact edge(s)* 
An�� contact edge connections that are not 
being used must be permanentl�� bridged 
using one o� the supplied 8.2 kΩ resistors
‑  Observe the mech. assembl�� instructions 
‑  Check transmission coil cores �or abrasion. 
‑  Check cable loop; make certain that both 
‑  Check cable / gate lea� contact points.
‑  Check suppl�� voltage**
- Check the connections o� the corresponding 
‑  Check sa�et�� contact edge(s)* 

Error correction

contact edge (squeezed or brittle suppl�� 
lines, etc.)
(ISK sa�et�� transmission s��stem)
transmission coil cores are in the cable loop
contact edge (squeezed or brittle suppl�� 
lines, etc.)
19