Technical Data - Schwamborn BEF 204 Traduction Du Manuel D'utilisation Original

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 21
EN Floor milling machine BEF 204
7 Troubleshooting
7 Troubleshooting
Only suitably knowledgeable, qualified profes­
sional technicians may perform repairs on the
machine.
Observe the safety instructions in Chapter 2.
Malfunction
Cause
The machine
The voltage supply has not
does not start
been properly connected.
Connecting cable is defec­
tive.
On/Off switch [3] is faulty.
Faulty capacitor.
Milling rotor does
Damaged belt.
not turn
No power to motor.
Uneven cutting
The belt slips.
Milling discs are jammed,
damaged or worn.

8 Technical data

Rated power
Rated voltage
Rated frequency
Rated current
Milling rotor speed
Protection rating
Dust extraction
Working width
Working to edge
Weight
Noise level Lpa
Noise level Lwa
Vibration, total value *)
*) Determined under standardised manufacturer operating conditions according to the HARM measuring me­
thod.
20
Rectification
Join the connecting cable (extension cable) with the proper
power socket and plug the connection cable's coupling in the
power plug [13, Fig. A/C].
Replace connecting cable.
Replace On/Off switch
Replace capacitor.
Replace belt.
Tighten belt
Clean or replace milling discs
Adjust the milling rotor working depth.
BEF 204
2,2 kW
230 V
50 Hz
13 A
‐1
1675 min
IP23
 50 mm
200 mm
10 mm
about 48 kg
89 dB(A)
101 dB(A)
2
± 2,7 m/s

Publicité