Installing the undersink unit

Note: An air gap of at least 50 mm at the left of the unit must be provided for
adequate ventilation. If the unit is to be operated inside a cupboard, the supplied
silicone buffers should be affixed to the inside edge of the cupboard doors and
the ventilation grills should be installed.
Optional the ventilation grills should be installed, if the temperature rises above
35 °C in the cupboard.
Please note the installation drawing below:
A
285.00
B
314.00
326.00
A
C
27
Note: If you using the vent tray kit KXB
see chapter 'Installation with KXB' for
attaching the venting cut outs.
The cut outs A and B can be covered with
the provided ventilation grilles.
The provided ventilation shaft has to be
mounted on the device and placed in
the cut out C. It will lead the warm air
under the cupboard floor, from where it
can escape through cut out A. To be able
to position the ventilation shaft over cut
out C, the cut out must be placed mini-
mum 65 mm in front of the back plate,
min. 455 mm from the left side wall and
min. 132 mm to the front cover.
There must be a distance from at least
10 cm between the cut outs A and B, to
avoid a thermal short circuit.