22/30
Operation
9.3.3
Determining the upper and lower stroke limitation
Button / display
or
or
P06
P07
Button [1]
Between upper and lower user height, there must be a minimum distance
so that the table is still able to move after the setting.
9.3.4
Deleting the stroke limitation
Button / display
or
or
P06
P07
Button [1]
9.3.5
Referencing
During referencing, the lifting modules move asynchronously and the
stroke limitations are deactivated for the stroke detection.
The user must ensure a free movement path, must monitor the movement
and cancel it, if necessary.
Button / display
9.4
Environmental factors
Avoid contact with liquids. See section "Technical data".
Bosch Rexroth AG, MPS: Control unit, 3 842 559 935/2019-08
Instructions
Move table to desired height
Call menu
Push to select a menu item
Lower stroke limitation
Upper stroke limitation
Push to confirm menu item
Instructions
Moving to the upper or lower stroke limitation
Call menu
Push to select a menu item
Lower stroke limitation (lifting module must be in the lowest position)
Upper stroke limitation (lifting module must be on the topmost position)
Push shortly to confirm the deletion
A tone sequence resounds if the deletion was successful
Instructions
Push shortly four times in a row
The display shows "= = ="
Keep pushed until the lifting module has moved to both end positions
"_ _ _" flashes during the retraction and "¯ ¯ ¯" during the extension.