7.3
Electrical connection of the product
Fig. 6: Electrical connection of the product
A:
Lifting module 1
(+ connection adapter for
collision protection, optional)
C:
Lifting module 3
Up to three lifting modules can be connected to the control unit.
Use:
- Connection A with one lifting module
- A and B with two lifting modules
- A to C with three lifting modules
C
2.
B
A
B:
Lifting module 2
D:
Hand switch / distribution
3 842 559 935/2019-08, MPS: Control unit, Bosch Rexroth AG
Installation
1.
D
17/30