Fuse/Circuit Breaker; Total Circuit Ampacity; Ground Fault Circuit Interrupter - Manitowoc NEO UD0140A Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation Instructions
Electrical Service
GENERAL
!
All wiring must conform to local, state and national
codes.
! Caution
Operate equipment only on the type of electricity
indicated on the specification plate.
VOLTAGE
The maximum allowable voltage variation is  10% of
the rated voltage on the ice machine model/serial
number plate at start-up (when the electrical load is
highest).
The 115/1/60 ice machines are factory pre-wired with a
8' power cord, and NEMA 5-15P-plug configuration.
The 208-230/1/60 and 230/50/1 ice machines are
factory pre-wired with a 8' power cord only, no plug is
supplied.

FUSE/CIRCUIT BREAKER

A separate fuse/circuit breaker must be provided for
each ice machine.
!
The ice machine must be grounded in accordance
with national and local electrical codes.
8
Warning
Warning

TOTAL CIRCUIT AMPACITY

The total circuit ampacity is used to help select the wire
size of the electrical supply.
The wire size (or gauge) is also dependent upon
location, materials used, length of run, etc., so it must be
determined by a qualified electrician.

GROUND FAULT CIRCUIT INTERRUPTER

Ground Fault Circuit Interrupter (GFCI/GFI) protection is
a system that shuts down the electric circuit (opens it)
when it senses an unexpected loss of power,
presumably to ground. Manitowoc does not recommend
the use of a GFCI/GFI circuit protection with our
equipment. If code requires the use of a GFCI/GFI then
you must follow the local code. The circuit must be
dedicated, sized properly and there must be a panel
GFCI/GFI breaker. We do not recommend GFCI/GFI
outlets as they are known for more intermittent nuisance
trips than panel breakers.
!
If the supply cord is damaged, do not operate the
equipment until the cord is replaced by a service
agent or similarly qualified person.