5-3. Control Box Connections

5-4. 14-Pin Plug Information

J
A
K
I
B
L
H
N
C
M
G
D
F
E
*The remaining pins are not used.
OM-252717 Page 16
1
Pin*
A
24 volts AC with respect to socket G.
B
Contact closure to A completes 24 volts AC contactor control circuit.
G
Circuit common for 24 volts AC circuit.
C
+10 volts DC input from power source to wire feeder with respect to socket D.
D
Remote control circuit common.
E
0 to +10 volts DC output signal from wire feeder to power source with respect to socket D.
H
Voltage feedback; 0 to +10 volts DC, 1 volt per 10 arc volts.
F
Current feedback; 0 to +10 volts DC, 1 volt per 100 amperes.
1
Interconnecting Cables
2
Interconnecting Cable
Receptacles
3
14-Pin Cord
2
3
Pin Information
Ref. 803187-B / Ref. 803197-B