Fuel Cap
Fuel Shut-off - OPEN 
Fuel level - Maximum
Do not overfill 
Assembly
Throttle Control Conversion
The standard engine has a manual throttle control. To operate with the manual throttle
control, to install a remote throttle control, or to convert to a fixed speed, follow the
appropriate instructions below. 
Note:  After installation, the engine speed may need to be adjusted to meet the
equipment manufacturer's performance specifications. Contact a Briggs & Stratton
Authorized Service Dealer for assistance. 
Manual Throttle Control
See Figure: 6
1.
Move the throttle control / TransportGuard® lever (A, Figure 6) to the OFF
position. 
2.
Remove the spring (S, Figure 6).
Remote Throttle Control with Braided Wire Cable
A remote throttle control with a braided wire cable can be installed in either of two
directions; Cylinder Head Direction or Front Direction. 
Cylinder Head Direction 
See Figure: 4, 6
1.
Move the throttle control / TransportGuard® lever (A, Figure 4) to the FAST
position. 
2.
Use a 10 mm wrench and loosen nut (P, Figure 6) ½ turn on the throttle control /
TransportGuard® lever (A).
3.
Hold the cable mounting nut (J, Figure 4) with a 10 mm wrench and loosen screw
(K).
4.
Install the cable wire (L, Figure 4) through the hole in the cable mounting nut (J)
and tighten screw (K). Make sure that the cable wire (L) does not extend more
than ½" (12,7 mm) past the hole. 
5.
Loosen the screw (I, Figure 4). Secure the cable sleeve (N) under the cable
clamp (M) and tighten the screw (I). 
6.
To check the operation of the remote throttle control, move the remote throttle
control from slow to fast a few times. The remote throttle control and the cable
wire (L, Figure 4) should move freely. Adjust nut (P, Figure 6) as needed for
desired operation.
Front Direction 
See Figure: 5, 6
1.
Move the throttle control / TransportGuard® lever (A, Figure 5) to the FAST
position. 
2.
Use a 10 mm wrench and loosen nut (P, Figure 6) ½ turn on the throttle control /
TransportGuard® lever (A).
3.
Hold the cable mounting nut (J, Figure 5) with a 10 mm wrench and loosen screw
(K).
4.
Install the cable wire (L, Figure 5) through the hole in the cable mounting nut (J)
and tighten screw (K). Make sure that the cable wire (L) does not extend more
than ½" (12,7 mm) past the hole. 
5.
Loosen the screw (I, Figure 5). Secure the cable sleeve (N) under the cable
clamp (M) and tighten the screw (I). 
6.
To check the operation of the remote throttle control, move the remote throttle
control from slow to fast a few times. The remote throttle control and the cable
wire (L, Figure 5) should move freely. Adjust nut (P, Figure 6) as needed for
desired operation.
Remote Throttle Control with Solid Wire Cable
A remote throttle control with a solid wire cable can be installed is any of four
directions; Cylinder Head Direction, Front Direction, Left Direction, or Right
Direction. 
Cylinder Head Direction 
See Figure: 6, 7 
1.
Move the throttle control / TransportGuard® lever (A, Figure 6, 7) to the OFF
position. 
8
2.
Fuel Shut-off - CLOSED 
3.
4.
5.
6.
7.
Front Direction 
See Figure: 6, 8 
1.
2.
3.
4.
5.
6.
7.
Left Direction 
See Figure: 6, 9 
1.
2.
3.
4.
5.
6.
7.
8.
Right Direction 
See Figure: 6, 10 
To install a remote throttle control from the right direction, a cable mounting bracket (U,
Figure 10, part number 596950) is required. To purchase a cable mounting bracket,
contact a Briggs & Stratton Authorized Service Dealer. 
1.
2.
3.
4.
5.
6.
7.
Remove the spring (S, Figure 6, 7).
Move the throttle control / TransportGuard® lever (A, Figure 6, 7) to the FAST
position.
Use a 10 mm wrench and loosen nut (P, Figure 6) ½ turn on the throttle control /
TransportGuard® lever (A).
Install the Z-fitting of the solid wire cable (Q, Figure 7) to either one of the small
holes in the bellcrank (R).
Loosen the screw (I, Figure 7). Secure the cable sleeve (N) under the cable
clamp (M) and tighten the screw (I). 
To check the operation of the remote throttle control, move the remote throttle
control from slow to fast a few times. The remote throttle control and the solid
wire cable (L, Figure 7) should move freely. Adjust nut (P, Figure 6) as needed
for desired operation.
Move the throttle control / TransportGuard® lever (A, Figure 6, 8) to the OFF
position. 
Remove the spring (S, Figure 6, 8).
Move the throttle control / TransportGuard® lever (A, Figure 6, 8) to the FAST
position. 
Use a 10 mm wrench and loosen nut (P, Figure 6) ½ turn on the throttle control /
TransportGuard® lever (A).
Install the Z-fitting of the solid wire cable (Q, Figure 8) to either one of the small
holes in the bellcrank (R).
Loosen the screw (I, Figure 8). Secure the cable sleeve (N) under the cable
clamp (M) and tighten the screw (I). 
To check the operation of the remote throttle control, move the remote throttle
control from slow to fast a few times. The remote throttle control and the solid
wire cable (L, Figure 8) should move freely. Adjust nut (P, Figure 6) as needed
for desired operation.
Move the throttle control / TransportGuard® lever (A, Figure 9) to the OFF
position. 
Remove the spring (S, Figure 6).
Move the throttle control / TransportGuard® lever (A, Figure 9) to the FAST
position. 
Use a 10 mm wrench and loosen nut (P, Figure 6) ½ turn on the throttle control /
TransportGuard® lever (A).
Remove the throttle control knob (W, Figure 9) to expose the small hole (S).
Install the Z-fitting of the solid wire cable (L, Figure 9) to the small hole (S) in the
throttle control lever (A).
Loosen the screw (I, Figure 9). Secure the cable sleeve (N) under the cable
clamp (M) and tighten the screw (I). 
To check the operation of the remote throttle control, move the remote throttle
control from slow to fast a few times. The remote throttle control and the solid
wire cable (L, Figure 9) should move freely. Adjust nut (P, Figure 6) as needed
for desired operation.
Move the throttle control / TransportGuard® lever (A, Figure 6, 10) to the OFF
position. 
Remove the spring (S, Figure 6).
Remove the throttle control knob (W, Figure 10) to expose the small hole (S).
Move the throttle control / TransportGuard® lever (A, Figure 6, 10) to the FAST
position. 
Use a 10 mm wrench and loosen nut (P, Figure 6) ½ turn on the throttle control /
TransportGuard® lever (A).
Install the Z-fitting of the solid wire cable (L, Figure 10) to the small hole (S) in the
throttle control lever (A).
Remove the bolt (T, Figure 10). Install the cable mounting bracket (U) to the
location as shown in Figure 10. Secure the cable mounting bracket (U) with the
bolt (T). Tighten the bolt (T) to 30 lb-in (3,4 Nm). 