8 - MAINTENANCE
8.13 - ELECTRONIC ANODE
The unit is equiped with a dynamic system for the tank active
protection from corrosion.
The anode is in active titanium.
Periodical substitutions are not foreseen.
Blue led = supplied current impressed to the anode
A
B
Green led = power supply OK
Diagnostics
Blue led
Green led
Description
OFF
OFF
Not feeded
ON / BLINK
ON
Operating / protection OK
Electrode in short-circuit
BLINK
BLINK
(simultaneous flashing)
Electrode not connected / no
BLINK
BLINK
water (alternated flashing)

8.14 - EXTRAORDINARY MAINTENANCE

It is possible to execute operations on the water components
without empty the strage tanks.
Close the aqueduct tap (A).
Close taps B and C.
A
B
A
B
C
83