7 - CONTROL
Password-protected unit parameters (installer use)
645
PWRes
Integration resi stance absorbed capacity
670
TLimiteCool
Inlet water temp under which comp activation in COOL is permitted
671
TLimiteHeat
Inlet water temp under which comp activation in HEAT is permitted
845
TypeTerm
Enabling of switch between heat pump and boiler in relation to COP
0 = function disabled (default setting)
1 = switch between heat pump and boiler in relation to SCOP
846
EnClimatica
Type of terminal connected (considering the one used the most)
0=Radiant panels
1=Fan coil
2=Radiator
847
CostoGas
Operation with climatic curve active or not
0 = operation with fixed point
1 = operation with climatic curve
848
CostoEle
Fuel cost in €/m
857
DlyPumpSec
Pump switchin off delay after absence of call/circuit Of
858
TimeLimitTemp
Maximum permanence time for secondary temperature out of limits
864
MaxTempH2OHeatC
Circuit 1 maximum discharge temperature in HEAT
1
865
MinTempH2OCoolC1 Circuit 1 minimum discharge temperature in COOL
866
DeltaTPumpC1
Circuit 1 nominal temperature leap
BandaDeltaTPumpC1 Centred band for DeltaTPump1
867
868
MaxSignalPumpC1
Maximum circulator 1 control signal
869
MinSignalPumpC1
Minimum circulator 1 control signal
870
ModoUtilizzoC1
Circuit 1 seasonal activation
1= Only COOL
2= only HEAT
3= Always
871
ChiamataUtilizzoC1
Configure environment call on circuit 1
0=From digital inlet
1=From thermostat
2=Both
891
ModoUtilizzoC2
Circuit 2 seasonal activation
1= Only COOL
2= only HEAT
3= Always
892
EnAntiRugC2
Enable circuit 2 anti-dew compensation
894
MaxTempH2OHeatC
Circuit 2 maximum discharge temperature in HEAT
2
895
MaxTempH2OCoolC2 Circuit 2 minimum discharge temperature in COOL
896
DeltaTPumpC2
Circuit 2 nominal temperature leap
897
BandaDeltaTPumpC2 Centred band for DeltaTPump2
898
MaxSignalPumpC2
Circulator 2 maximum control signal
899
MinSignalPumpC2
Circulator 2 minimum control signal
909
ChiamataUtilizzoC2
Configure environment call on circuit 2
0=From digital inlet
1=From thermostat
2=Both
3
Tab.3