Safety instructions

All safety instructions must be observed and followed.
Failure to follow the safety instructions may lead to serious injury or death or cause
environmental and/or property damage.
Adherence to the safety instructions contained in these operating instructions will help you
to avoid risks, to operate the pump efficiently and to ensure that the product is used to its
full potential.
Safety instructions on the activities are listed at the start of the respective chapter and the
attachments.
Special safety instructions on individual action steps are given under the respective
action step.
Attention!
Danger from splashing liquids!
Attention!
Attention!
Attention!
30/88
Original operating instructions Eccentric worm drive pump F 550 and Sanitary pump F 560
Make sure that the operator has read and understood the operating
instructions.
Check the motor, mains plug, pump and hose regularly for operating
safety.
The maximum operating pressure and the operating temperature
must not be exceeded.
High operating pressure may result in the containers or the hoses
bursting or becoming loose. Make sure that excessive pressure
does not result when filling a container.
Keep the air escaping and the displacement in mind when immer-
sing the pump in the liquid. Lower the pump carefully.
Fill carefully and at an appropriate speed to avoid leakage of the
liquid. Install appropriate splashguards for open barrels or contain-
ers.
After the filling, allow the excess to drip off the hand nozzle.
There may be liquid left in the outlet tube, which will then leak out.
Empty the pump, hose and fittings prior to removing the motor.
Remove spilled liquid from the floor and dispose of it in an environ-
mentally sound manner.
The maximum pressure of 8 bars must strictly be observed.
Only use couplings between motor and pump that are suitable for
use in category 2 (zone 1) and for explosion groups IIB or IIC.
The temperature class of the coupling must at least correspond to
the temperature class of the pump (e.g. pump with T4 -> coupling
T4, T5, T6).
Observe the operating and assembly instructions for the coupling
used.
Risk of injury due to open drive shaft.
Never operate motors without pump!