TROUBLESHOOTING
The indications provided by the LEDs present on the Emitter and Receiver units make it
possible to trace the cause of a system malfunction.
As indicated in the "SIGNALS" chapter of this manual, in the case of a fault, the system is
blocked and the type of fault can be identified by the LEDs present on the Emitter and
Receiver units. (See the tables below).
EMITTER
MEANING
Internal error
(add-on board)
Internal error
(master board)
RECEIVER
MEANING
Internal error
OSSD static
outputs error
Overload of the
OSSD static
outputs
OSSD1 - OSSD2
short-circuit
Interfering
dangerous
Emitter detected.
The receiver is
able to receive
simultaneously the
beams from two
different Emitters
24
LED
RED (2)
GREEN (3)
ON
OFF
ON
OFF
LED
RED (5)
GREEN (7)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
6 consecutive
ON
OFF
(TEST)
YELLOW (1)
blinking
every 2,5sec
Send the equipment for repair
to SCHMERSAL.
blinking
every 0,8sec
(CLEAR)
(OSSD)
YELLOW (4)
RED (6)
2 / 3
consecutive
OFF
pulses
2 consecutive
OFF
pulses
3 consecutive
OFF
pulses
4 consecutive
OFF
pulses
OFF
pulses
REMEDY
REMEDY
Send the equipment for repair
to SCHMERSAL.
Carefully check the connection
of terminals 1 and 3 (OSSD) on
the connector. If necessary,
adjust load reducing the current
required to max 500 mA (2 F)
Carefully check the connection
of terminals 1 and 3 (OSSD) on
the connector. If necessary,
adjust load reducing the current
required to max 500 mA (2 F)
Carefully check the connection
of terminals 1 and 3
Carefully locate the interfering
Emitter and take action in one
of the following ways:
Switch the position of the
Emitter and Receiver.
Move the interfering Emitter
to avoid this illuminating the
Receiver.
Shield the beams coming
from the interfering Emitter
using opaque protections.