Vertical Position Of The Light Curtain / Light Grid - schmersal SLC 210 Instructions De Montage

Masquer les pouces Voir aussi pour SLC 210:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

VERTICAL POSITION OF THE LIGHT CURTAIN / LIGHT GRID

30 mm and 40 mm resolution models
These models are suitable for the protection of
hands.
The minimum safety distance S is calculated
according to the following formula:
S = 2000(t
This formula is valid for distances S between 100
and 500 mm. If this formula results in S being
greater than 500 mm, the distance can be reduced
to a minimum of 500 mm by means of the following
formula:
S = 1600(t
If, due to the specific configuration of the machine,
the dangerous area can be accessed from above,
the highest beam of the light curtain / light grid must
be at a height H of at least 1800 mm from the base
G of the machine.
Multibeam Models.
These models are suitable for the protection of
the entire body and must not be used to protect
arms or legs.
The minimum safety distance S is calculated according
to the following formula:
The recommended height H from the base (G) must be the
following:
MODEL
SLG 210-E/R0500-02-RFLC
SLG 210-E/R0800-03-RFLC
SLG 210-E/R0900-04-RFLC
+ t
) + 8(D-14)
1
2
(D=resolution)
+ t
) + 8(D-14)
1
2
S = 1600 (t
+ t
) + 850
1
2
BEAMS
lightcurtain
direction
of
approach
reference plane (G)
light grid
direction
of
approach
reference plane (G)
Recommended Height H (mm)
400 – 900
2
300 – 700 – 1100
3
300 – 600 – 900 - 1200
4
point of
danger
Figure 4
point of
danger
Figure 5