L.B. White 346 Manuel De L'utilisateur page 11

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Classic Agricultural Animal Confinement Building Heaters
application of pipe compound before further
tightening.
-- Tighten the gas connections as necessary to stop
the leak.
-- After all connections are checked and any leaks
are stopped, turn on the main burner.
-- Stand clear while the main burner ignites to
prevent injury caused from hidden leaks that could
cause flashback.
-- With the main burner in operation, check all
connections, hose connections, fittings and joints
as well as the gas control valve inlet and outlet
connections with approved gas leak detectors.
-- If a leak is detected, check the components
involved for cleanliness in the thread areas and
proper application of pipe compound before
further tightening.
-- Tighten the gas connection as necessary to stop
the leak.
-- If necessary, replace the parts or components
involved if the leak cannot be stopped.
-- Ensure all gas leaks have been identified and
repaired before proceeding.
12. A qualified service agency must check for proper
operating gas pressure upon installation of the
heater.
13. Light according to instructions on heater or
within owner's manual.
14. It is extremely important to use the proper size
and type of gas supply line to assure proper
functioning of the heater. Contact your fuel gas
supplier for proper line sizing and installation
15. Ensure the heater has the proper gas regulator
for the application. A regulator must be con-
nected to the gas supply so that gas pressure
at the inlet to the gas valve is regulated within
the range specified on the dataplate at all times.
Contact your gas supplier, or the L.B. White Co.,
LLC. if you have any questions.
16. This heater can be configured for use with
either L.P. gas vapor withdrawal or natural gas.
Consult the dataplate for the gas configuration of
the specific heater. Do not use the heater in an
L.P. gas liquid withdrawal system or application.
If you are in doubt, contact the L.B. White Co.,
LLC.
17. Eventually, like all electrical/mechanical devices,
the thermostat can fail. Thermostat failure may
result in either an underheating or overheating
condition which may damage critical products
and/or cause animal injury or death. Critical
products and/or animals should be protected by
a separate back-up control system that limits
high and low temperatures and also activates
appropriate alarms.
18. Take time to understand how to operate and
maintain the heater by using this Owner's
Manual. Make sure you know how to shut off
the gas supply to the building and also to the
individual heater. Contact your fuel gas supplier
if you have any questions.
19. Any defects found in performing any of the
service or maintenance procedures must be
eliminated and defective parts replaced immedi-
ately. The heater must be retested by properly
qualified service personnel before placing the
heater back into use.
Owner's Manual • Classic
11