Fig. 27
Fig. 28
Fig. 29
• Using the supplied Hex Key, release the arbor screw and
remove the washer and blade flange and the blade from
the arbor. (Fig. 27)
Note: The arbor screw has a LH thread. Turn clockwise to
loosen. Turn counterclockwise to tighten.
• Install the new ø210 mm blade. Make sure the rotation arrow
on the blade matches the clockwise rotation arrow on the
upper guard.
Note: The blade teeth should always point downward at the
front of the saw.
• Install the blade flange, washer and arbor screw.
• Lock the arbor and tighten the arbor screw using moderate
force, but do not overtighten.
• Replace the guard operating arm and its retaining
pivot screw. (Fig. 28)
• Ensure the Hex Key is removed and the arbor lock has
released before operating.
• Ensure the blade guard is fully functional before using
the machine.
If required, Blade Bore Reducing Inserts should only be used
in accordance with the manufacturers instructions.
(8.12)
USE OF OPTIONAL EVOLUTION ACCESSORIES
(not supplied as original equipment – see Additional Accessories)
(8.13)
DUST BAG
A Dust Bag can be fitted to the extraction port at the rear of
the machine. The Dust Bag is for use when cutting wooden
materials only.
• Slide the Dust Bag over the dust extraction port, ensuring
that the spring clip grips the port holding the Dust Bag
securely in place. (Fig. 29)
26
www.evolutionpowertools.com