Troubleshooting - Cooke & Lewis CLMIRAG90-C Mode D'emploi

Masquer les pouces Voir aussi pour CLMIRAG90-C:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Troubleshooting

GB
IE
Troubleshooting
Fault
Excessive
vibration.
Light on, but
motor does not
work.
Both light and
motor do not
work.
Suction
performance
reduced.
Works normally
but cooking
smells linger.
14
Cause
The appliance is not
installed properly on the
brackets.
The fan blade is
damaged.
tightly.
The fan blade is jammed.
The motor is damaged.
Light bulb blown.
Power connection loose.
Speed may be too low.
Distance between the
cooker hood and the hob
is too great.
dirty.
Top vent might be
obstructed.
Optional vent kit might be
twisted.
in recirculation mode or
grease.
CLMIRAG90-C Cooker Hood
Solution
Take down the appliance and
Switch off the appliance. Repair
service personnel only.
Replace with a bulb with correct
rating.
Check power supply.
Select a higher speed.
Readjust the distance to:
Gas hobs: 750mm
Electric hobs: 650mm
Care and
maintenance section.
Clear any obstruction.
the manufacturers instructions.
maintenance section.
Care and

Publicité