Mesto PICO 3232 Mode D'emploi page 18

Masquer les pouces Voir aussi pour PICO 3232:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
EN
Observe the legal requirements of your country for accident prevention and check
the device in regular intervals.
Unless otherwise specified, we recommend that an expert carries out an external
test every 2 years and an internal test every 5 years as well as a strength test every
10 years.
Faults
Use only original spare and accessory parts.
Fault
No pressure builds up in
the device
Liquid flows out of the
pump
No tank pressure
indication on the piston
pressure gauge,
Safety valves blow off too
early.
The nozzle does not
spray even though pres-
sure is present
Only spray, no atomiza-
tion
The shut-off valve does
not close.
Liquid emerges without
the lever being activated.
Contact address for additional information → see title page.
Cause
The pump is not screwed on
tightly.
O-ring [17] on the pump is
faulty. (Fig. 15)
Diaphragm [18] is defective.
(Fig. 15)
Valve disc [21] dirty or defecti-
ve. (Fig. 19)
Piston pressure gauge [14] is
defective
Filter [20] (Fig. 18) and / or
nozzle [13] (Fig. 17) is clogged.
Insert [12] is missing (Fig. 17)
O-rings [22] of the pressure bolt
[23] not greased / lubricated.
(Fig. 20)
Defective pressure bolt [23] or
O-rings [22] (Fig. 20)
18
ENGLISH
Remedy
Screw the pump on tightly.
Replace the O-ring.
Replace the diaphragm.
(Dismantle or assemble the
pump → section „Care and
maintenance")
Clean or replace the valve
disc.
For safety reasons, it is not
possible to replace the safety
valve/piston pressure gauge.
Please contact your local
MESTO specialist or MESTO
directly.
Clean the filter or / and
nozzle.
Position the insert in the
nozzle
Grease the O-rings of the
pressure bolt
Replace the pressure bolt or
O-rings.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Herbi 3232u

Table des Matières