Connecting an external button (230V/50Hz) ( Figure
... for the subsequent adjustment the limit stops
12
(a)
(b)
(c)
Using the setting wire
The setting wire is used to transfer the motor set button function to the outside. If
the setting wire is connected to an external button (see above), this external button
can be used as a set button for adjusting the limit stops.
Guide the setting wire (j)) of the motor cable (15) to the respective switch
(e.g. to the switch box).
(21)
Connecting a corded switch-setting device
Adjusting the end points before connecting the wires
If you want to adjust the end points of the tubular motor before connecting the
wires, you can do so using a corded switch-setting device (21) (art. no. 4090,
available from specialist shops).
Pulling off the motor cable (15) can pose a risk to life.
Make sure that the motor cable (15) is not taken up or pulled off by the winding
shaft (5) while making adjustments.
40
D
ES
F
(j)
(i)
(h)
(d)
(e) (f)
(g)
GB NL
Key
(a) =
Set button (11)
(b) =
Control device (e.g. single-pole switch/button)
(c) =
Main 230V/50Hz
(d) =
Switch box
Terminal configuration
(e) =
PE
green/yellow
(f) =
N
blue
(g) =
L1
black
(h) =
( ) black
(i) =
( ) brown
(j) =
white (Setting wire)
(k) =
external button
IMPORTANT
Disconnect the external button again once the limit stops have been adjusted and connect the setting wire (j) to
(k)
the neutral conductor (f), see figure
Using the setting wire (j) when installing the device for the first time
When installed for the very first time, the roller shutter fitter can connect the entire
motor supply cable to a switch setting device (21) (art. no. 4090) which can then
be used to adjust the tubular motor limit stops.
Using the setting wire (j) to change the limit stops retrospectively:
If you want to change the limit stops of an existing roller shutter installation, all
your electrician needs to do is to connect the setting wire (j) to a conventional
external switch (230 V/50 Hz) in accordance with the connection diagram
This switch can then be used in conjunction with your shutter control device to change the
limit stops.
Using the setting wire (j) after having adjusted the limit stops:
Once the limit stops have been adjusted, the relevant external switching device
must be disconnected and the motor must be connected again in accordance with
the connection diagram, see figure
IMPORTANT
The setting wire (j) must be connected to the neutral conductor (f)
once the limit stops have been adjusted.
Open the terminal clamp by pressing the lifter and connect all
1.
of the tubular motor cable cores according to their functions,
see figure
) ...
.
.
.
GB
.