5.5 Electrical connection
5.5.1 Voltage supply / supply network connection
Danger
Risk of death by electric shock!
Components have voltage applied.
Contact with current conducting parts results in an electric
shock, burns or death.
When working with the electrical system, the following
points must be observed:
Disconnect device from voltage.
Secure device from being turned back on.
Ensure that no voltage is applied.
Earth and short-circuit the unit.
Cover neighbouring componets that are under voltage
and secure the danger area.
During installation, the following points must also be
observed:
The electrical installation, setting-up and maintenance of
the device may only be carried out by qualified
electricians and in compliance with the applicable
national regulations (see chapter entitled 2.4
"Qualification of Personnel" on page 3).
Before connecting the device, caution must be taken to
ensure that it is free of voltage or the appropriate
protective measures have been taken.
Note the following points when connecting to the power
supply:
Observe DIN VDE 0100 Part 530 for installation in
Germany.
Observe the applicable national / local regulations when
installing in other countries.
Ensure a clockwise rotating field for a three-phase
connection.
13
5.5.2 Safeguarding and personal protection
Danger
Danger to life by electric shock
RCCBs (type B) sensitive to universal currents may not
installed behind RCCBs (type A) sensitive to pulse currents.
Depending on the equipment package, the charging stations
are fitted with the required safety equipment according to
the following table.
Version
Light, Pro, Basic
(3.7 kW / 7.4 kW)
single-phase
Light, Pro, Basic
(11 kW / 22 kW) three-
phase
Start E, Standard E,
Basic E
(3.7 kW / 7.4 kW single-
phase)
(11 kW / 22 kW three-
phase)
Basic R
(3.7 kW / 7.4 kW single-
phase)
Basic R
(11 kW / 22 kW three-
phase)
RCCB
RCCB
type A
type B
—
—
—
—
—
—
CB
—
—
—