ELECTRONIC PROGRAMMER (SL70M)
The incorporated electronic programmer is fitted with all the connections
needed to carry out an automatic installation and comes complete with
electronic torque regulation.
The appliance is fitted with an interface for the insertion of a standard radio
receiver card.

ELECTRICAL CONNECTION

• Before connecting the appliance make sure that the voltage and frequency
rated on the data plate conform to those of the mains supply.
Warning! An all pole trip switch with a least 3 mm between the
contacts must be installed between the unit and the mains supply.
• Connect the control and security device wires.
• Connect the power supply cable to the mains.
• Do not use cables with aluminium conductors; do not solder the ends of
cables which are to be inserted into the binding posts; use cables which
are marked T min 85°C and are resistant to atmospheric agents.
• The terminal wires must be positioned in such a way that both the wire
and the insulating sheath are tightly fastened (a plastic jubilee clip is
sufficient). Where possible use the supplied cable clamp.
Terminal board connection (fig.13)
1
Programmer 230 Vac power supply live wire
2
Programmer 230 Vac power supply neutral wire
3-4-5
Motor command wires (common, opening, closing)
6
Motor earth wire
7
Electronic programmer earth wire
8-9
Door security contact
10-11
24 Vac 10 W output; warning lights
(intermittent or continuous activation selected via jumper).
12-13
24 Vac 3 W in output; Indicator light (indicates that the gate is
moving and switches off at the end of the cycle).
24 Vac 5 W in output; powering external devices.
14-15
TA (contact normally open) opening button in input.
16
17
TC (contact normally open) closing button in input.
18
Tb (contact N.C.) stop button input
(The opening of this contact interrupts the cycle until a new move-
ment command is given).
19
TD (contact normally open) dynamic button input "Open-block-
close-block or open-close with inversion only in the closing direction
depending on programming"
20
Common for all inputs and outputs.
21
TAL (contact normally open) limited opening button
22
Common for all inputs and outputs.
23
FTCS (normally closed contact) Safety and control devices in input
(stop photoelectric cells). The opening of this contact will block
all movement, until the obstruction has been removed, due to the
safety device cutting in, the door will then continue moving until
it reaches a travel limit (only in the automatic mode).
24
FTCI contact N.C.) Safety and control devices in input (photocells
invert the travel direction when an obstruction is detected). The
opening of this contact will provoke a travel direction inversion
during closure due to the cutting in of the safety device.
27
Inner conductor for radio receiver antenna (if an external antenna is
fitted use a coaxial type cable RG58 with an impedance of 50Ω)
28
Outer conductor for radio receiver antenna.
Note:
ALL UNUSED NC CONTACTS MUST BE JUMPED
Setting the torque limiter
The torque can be set to minimum, seeing as the appliance will give a
maximum power thrust each time it receives a movement command
Position "MAx"
equals: 230 Vac
"C"
equals: 195 Vac
Position
"b"
equals: 170 Vac
Position
Position
"A"
equals: 145 Vac
Position
"MIN"
equals: 120 Vac
Switch on the power and make sure that the red indicator LEDS are in the
following condition:
- L1
Power on LED
- L2
Time programming LED
- L3
Safety LED for the blocking button "Tb"
- L4
Safety LED for the inverting photoelectric cells "FTCI"
- L5
Safety LED for the stop photoelectric cells "FTCS"
Check that the activation of the safety devices switches the corresponding
LEDS off.
If the red power on LED doesn't light up check the condition of the fuses
and the power cable connection between binding posts "1"-"2" (fig.13).
If one or more of the safety LEDS do not light up check the contacts of the
relative security devices and check that the unused safety device contacts
have been bridged.
ELECTRONIC CARD DESCRIPTION
All rights reserved. Unauthorised copying or use of the information contained in this document is punisha
F1
2
1
L
N
Pb
10
11
12
LP
24V
24V
Legend
F1
3.15 A rapid action fuse (230 Vac, 50-60Hz power supply)
F2
1 A delayed fuse (24 V circuit )
FTb Access door security contact
J1
Motor direction selection jumper
J2
Warning light function mode selection jumper
J3
Third SEL interface button function mode selection jumper
J4
Second slot-in radio card channel/blocking button selection (to be
Drawing number :
DC0355
bridged if you are using a single channel card
J5
Block disabling bridge if you are not using an interface card
Product Code :
YPR300MM3
L1
Power on LED
L2
Date :
31-01-2002
Draft :
P.J.Heath
Time programming LED
L3
Safety LED for the blocking button "Tb"
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
L4
Safety LED for the inverting photoelectric cells "FTCI"
L5
Safety LED for the stop photoelectric cells "FTCS"
P1
Programming button
on
Pb
Door security contact exclusion jumper
off
R1
Standard slot-in receiver card interface
on
R2
Serial card interface
on
S1
Function selection dip-switch
on
S2
Torque limiter slide
S3
Motor direction switch right or left
15
F2
L1
R2
J5
L2
J3
J2
J1
1 2 3
P1
S1
L3 L4 L5
3
4
7
5
6
M
DX
SX
FTb
DX
13
14
15
16
17
18
19
20
TA
TC
TB
TD
TAL
LS
Description :
Scheda base orrizzontale fissa
YPR300 (scheda per SL70M)
13
CS1126 DC0351
J5
R1
J4
J4
J3
J2
J1
S3
SX
21
22
23
24