Electrical connection
Before connecting the appliance make sure that the voltage and frequency rated on the data plate
conform to those of he mains supply.
NB: The installer must set the torque selector switch to the appropriate voltage depending on the weight
and dimensions of the gate which is to be automated. The safety standards indicate a maximum thrust
at the head of the gate equal to 5 kg.
Carry out trial movements to verify the correct calibration of the system.
TERMINAL BOARD CONNECTIONS
1-2-3
Motor in output Opening- Closing- Common
4-5
Electronic programmer power supply 230 Vac 50/60 Hz
6
Earth binding post (mains supply)
7
Motor earthing wire (in output)
8-9
Common for all inputs and outputs (negative)
10
TAL Limited opening button with automatic or semi-automatic functions
11
TD (contact N.O.) Dynamic button in input "Open-Close"
12
TB (contact N.C.) Blocking button in input (The opening of this contact will interrupt the cycle until a
new movement command is given).
TC (contact N.O.) Closing button in input
13
14
TA (contact N.O.) Opening button in input
15-16
24 Vac 5 W in output, powering external devices (Photoelectric cells, etc.)
17-18
BSP Passive safety input (N.C.)
If this contact is open the power supply to the controls (including the electronic card) will be inter-
rupted. Insert a normally closed contact which is able to support a load of 30V dc 00 mA. This
safety device should be installed in addition to the normal active safety devices (Caution! This input
cannot be connected in series with the FTCI and FTCS as they do not share the same common). It
could also be wired in series to a fixed position anti-crush buffer or be used an emergency device in
line with the local standards in force.
Link this security feature to the active safety devices FTCI and FTCS as required by the safety stand-
ards in force.
19-20
Electronic locking device 2 Vac 2 W max. in output (only in opening direction)
21
Radio receiver antenna (N.B. The antenna must be connected using a coaxial cable RG58 with an
impedance of 50Ω)
22
Mass for radio receiver antenna
FCC closing travel limit in input (contact NC)
23
24
FCA opening travel limit in input (contact NC)
25
FTCS (contact N.C.) Safety and control devices in input.
(photoelectric cells stopping the gate when an obstruction is detected) The opening of this contact
will block all movement, during opening and closing, until the obstruction has been removed, due to
the safety device cutting in, the gate will then continue moving until it reaches a travel limit.
26
FTCI (contact NC) Safety and control devices in input (photo-cells invert the travel direction when an
obstruction is detected) The opening of this contact will provoke a travel direction inversion during
closure due to the cutting in of the safety device.
LS 24V ac 3W in output. Indicates an opening/closing cycle in course. It turns off at the end of the
27
cycle.
28-29
LP 24 Vac 5 W flashing warning lamps indicating gate in movement
N.B.: ALL UNUSED NC CONTACTS MUST BE JUMPED
21
22
8
9
10
NO NO NC NO NO
CS919 DC0210
23
24
25
26
27
28
29
NC NC NC NC
11
12
13
14
15
16
17
18
1
2
C.
M1
19
20
ELS
0
3
4
5
6
7
N
F
4