If the engine stops running without the indicator lighting up, then the oil level
isn't the issue. Try to restart the engine.
Engine Overload Indicator (J)
The overload indicator (Fig. 4-2) glows when
the connected electrical devices exceeds the
generator's wattage/amperage capacity or by
a power surge. The engine continues to run,
but power is no longer supplied to the
outlets until the generator is reset.
The engine overload indicator light may turn
on for a few seconds when attaching a load
due to a power surge. This is normal.
Resetting the Generator
1.
Disconnect all electronic devices, then stop the engine.
2.
Reduce the number of electric devices until the total wattage is within the
generator's rated output. Include the highest peak wattage in this calculation.
3.
Inspect the air inlet and control panel for any blockage. Remove
blockage if found.
4.
Restart the engine, then reconnect the electric devices.
AC Pilot Indicator (L)
The pilot indictor (Fig. 4-3) glows when the engine starts and the generator is
providing power.
ENGINE ECO CONTROL (R)
1.
Push the ECO toggle switch to activate the economy control unit. The
engine speed will increase or decrease based on the power needed for the
electric load. This improves fuel economy and reduced engine noise.
2.
When the ECO switch is in the OFF position, the engine runs at the rated
speed of 4,800 RPM.
3.
The ECO switch must be turned to the OFF position when using electronic
devices that require a large starting current, such as a compressor.