Problem(s)
Possible Cause(s)
Generator is
1. DC circuit breaker is OFF.
running, but
2. AC Pilot Light Indicator is
does not
supply power.
3. Poor connection.
4. Defective cord set.
5. Connected device is faulty.
6. Fault in generator.
Engine hunts
1. Choke was removed too
or falters
2. Clogged fuel filter
3. Carburetor is running too
WATTAGE REFERENCE CHART
Electric equipment, especially engine produce strong current when being
started. The following table offers references when you connect those
installations to the generator.
Tool or Appliance
Essentials
Light Bulb – 75 watt,
Deep Freezer
Sump Pump
Refrigerator / Freezer – 18 Cu. Ft.
Water Well Pump – 1/3 HP
Heating / Cooling
Window Air Conditioner – 10,000
BTU
Window Fan
Furnace Fan Blower – 1/2 HP
Visit www.princessauto.com for more information
2,000W Inverter Generator
off.
soon
rich or too lean
Suggested Solution(s)
1. Turn DC circuit breaker ON.
2. Stop engine and restart.
3. Check and repair.
4. Check and repair.
5. Connect a device that is working
properly.
6. Contact service department.
1. Move to choke until engine runs
evenly
2. Clean or replace fuel filler
3. Have technician adjust carburetor.
Rated *
(Running) Watts
75
500
800
800
1,000
1,200
300
800
8700718
Additional Surge
(Starting) Watts
-
500
1,200
1,600
2,000
1,800
600
1,300
29