Allow generator output to stabilize (engine and attached devices
run evenly) before plugging in the next load.
5.
Turn off the generator immediately if an appliance becomes sluggish,
stops suddenly or acts in an abnormal manner. Disconnect and inspect
the appliance.
6.
Reduce the electric load on the circuit if the circuit breaker trips. Wait a few
minutes before resuming operation.
7.
When using the AC and DC electrical output at the same time, do not
exceed the maximum output of the generator.
8.
Ensure a skilled electrician connects the generator when incorporating the
generator into a home power circuit. A properly installed transfer switch is
required. An improper connection can damage the house's electrical
system, generator and any attached appliances or cause a fire.
TURN OFF THE GENERATOR
IMPORTANT! To stop the generator in an emergency, turn the main generator
switch to the OFF position.
1.
Turn the ECO switch to the OFF position.
2.
Disconnect all electric devices from the generator.
3.
Turn the start switch to the OFF position.
4.
Rotate the gas cap to the OFF position to prevent air flow.

AC PARALLEL OPERATION

WARNING! Do not connect or disconnect the parallel cables when the
generators are running to avoid an electric shock.
The parallel outlets allow two 2,000W Inverter
Generators to be run together to increase the
rated output to 3.0 kV-A, and the rated
current to 25A/120V. The maximum power is
4.0 kV-A. This requires a parallel cable kit
(sold separately) (Fig. 7).
1.
Connect the two generators together with
the parallel cables.
2.
Make sure the ECO switch is set to the same position on both generators.
Visit www.princessauto.com for more information
2,000W Inverter Generator
8700718
Fig. 7
13