Trouble Shooting; Technical Specifications - Tennant B1 Serie Manuel Opérateur Et Piéces

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
EN
English

Trouble Shooting

Problem
Machine does not operate
Machine operates with a wobble or jerky
motion.
Machine circuit breaker trips continuously.

Technical specifications

A.C. motor
Rated power
Max.amp draw
Brush (rpm)
Brush (mm)
Working height (mm)
Working weight
Protection class
Belt- driven
Sound pressure level LPA
6
Cause
Faulty power cord.
Tripped circuit breaker
Faulty machine wiring.
Faulty motor.
Capacitor burned out.
Soiled Pad.
Improper pad/brush for application.
Pad driver/brush not installed correctly.
Pad/brush unevenly worn.
Pad not properly centered on pad driver
Heavily soiled pad/brush
Improper pad/brush for application
Defective circuit breaker.
Worn carbon brushes in motor.
B1
230 V: 50 Hz
1500 W
8,3 A
1100
510
250
46 kg
lPx0
x
67db (A)
Solution
Contact Service Center.
Wait 10 min. till machine cooled down and
try again.
Contact Service Center
Contact Service Center
Contact Service Center
Replace Pad
Change to proper pad/brush
Remove and reinstall pad driver/brush
Replace pad/brush
Remove and reinstall pad driver
Clean or replace pad/brush
Change to proper pad/brush
Contact Service Center
Contact Service Center
B1 9002027 (08- 16)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mb12004Mb12904

Table des Matières