TROUBLE SHOOTING
PROBLEM
Motor does not operate.
Machine circuit breaker trips
continuously.
Pad spins slowly or not at all.
SPECIFICATIONS
MODEL
WIDTH
HEIGHT
LENGTH
WEIGHT
DRIVE MOTOR
PAD/BRUSH SPEED
POWER CORD LENGTH
PAD DIAMETER
DECIBEL RATING AT
OPERATOR'S EAR, INDOORS ON TILE
FLOOR
BR- -1200- -NDC / BR- -1600- -NDC (04- -10)
CAUSE
Machine circuit breaker tripped.
(Spray buffing with the BR--1600--NDC
model is not recommended).
Building circuit breaker tripped.
Faulty power cord.
Faulty wiring.
Faulty twist grip switch.
Faulty Rectifier.
Faulty Motor.
Soiled Pad.
Improper pad for application.
Defective circuit breaker.
Worn carbon brushes in motor.
Loose drive belt.
Broken drive belt.
BR- -1200- -NDC
20.75 in / 530 mm
49 in / 1,240 mm
29.75 in / 760mm
68 lb / 31 kg
120 V, 1.5 hp, 15 A, 60 H
1,200 rpm
75 ft / 23 m Gauge 3 X 1.5 mm
20 in / 510 mm
70 dBA
Home
Find... Go To..
SOLUTION
Determine cause and reset breaker on
machine. Wait 15 seconds before
restarting machine.
Reset breaker and change to different
circuit.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Replace Pad.
Change to proper pad.
Contact Service Center.
Contact Service Center.
Tighten drive belt.
Replace drive belt.
BR- -1600- -NDC
20.75 in / 530 mm
49 in / 1,240 mm
29.75 in / 760mm
68 lb / 31 kg
120 V, 1.5 hp, 15 A, 60 H
Z
1,600 rpm
75 ft / 23 m Gauge 3 X 1.5 mm
20 in / 510 mm
70 dBA
OPERATION
EN
Z
9