1 Display
2 LEFT key
3 RIGHT key
4 OK button
5 ESC button
Faults recognised by the controller are
shown on the display in the plant and
stored in the error memory.
Currently pending faults are displayed in
succession at 2-second intrevals.
1 Error number
2 Total number of current faults
 Select the required group with the but-
tons LEFT and RIGHT.
 Press OK to retrieve the first error mes-
sage.
 Select further error messages with the
buttons LEFT and RIGHT.
 Press ESC to exit the function.

Fault display

Rectify faults
 Locate the description of the error
number in the table below and follow
the instructions to eliminate the fault.
 Press the emergency stop button, un-
lock it, and press the "Reset" key on the
control panel.
or
 Switch the main switch off and back on.
The fault is acknowledged.
Viewing the error memory
The following display can be seen in the in-
itial state:
Total
Truck
Press the OK button if current error mes-
sages appear instead.
Note
The current error messages are redis-
played when no button is pressed for 30
minutes.
Press the RIGHT and OK buttons at the
same time when you want to display the er-
ror messages before the 30 minutes have
elapsed.
Press the ESC button for 2 seconds if a dif-
ferent display appears instead.
 Press OK button for more than 2 sec-
onds.
13.08.2008
< Info
 Press the LEFT button.
Selection
Error memory
 Press the OK button.
Fault
Total: 05
The error memory is subdivided into 5
groups. Each group can store a maximum
of 40 faults. The most recent faults are at
the upper end of the group.
15
-
EN
=#####
=#####
15:54
Config.>
1-49
41