Kärcher TB 36 Notice Originale page 46

Masquer les pouces Voir aussi pour TB 36:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Dis-
Fault
play
169
Collective fault message high pressure pump
1
170
Collective fault message high pressure pump
2
171
Collective fault message high pressure pump
3
172
Anti-frost active (traffic signal forward and
backward blinks five times)
175
Trailer coupling detected
178
CAN bus fault in module A38 no connection
(intensive cleaning)
179
Excess current outlets CAN Bus module A38
(intensive cleaning)
180
CAN bus error, module A8, no connection (lift,
lower, drive portal)
181
CAN bus error, module A9, no connection
(high pressure distributor to portal)
185
CAN bus error, module A29, no connection
(pump switching cabinet)
187
CAN bus error, module A31, no connection
(Basic gate control)
188
CAN bus error, module A19, no connection
(Adv. control panel)
189
CAN bus error, module A20, no connection
(Adv. control panel)
190
Excess current outputs CAN bus module A8
(lift, lower, drive portal)
191
Excess current outlets CAN Bus module A9
(high pressure distributor to portal)
195
Excess current outlets CAN Bus module A37
(pump switching cabinet)
197
Excess current outputs CAN bus module A31
(Basic gate control)
198
CAN Bus error module 19 output overload
(Comfort operator station)
199
CAN Bus error module 20 output overload
(Comfort operator station)
200
Control voltage is missing
201
Plant not in operation (operational time
switched off)
203
Portal not in normal setting
204
Side-brushes not facing outwards
205
Side-brush 1 not facing outwards
206
Side-brush 2 not facing outwards
207
Release signal missing
208
Roof brush not facing upward
209
High pressure roof bar not up
220
Door 1 is not closed
221
Door 1 is not opened
222
Door 2 is not closed
223
Door 2 is not opened
46
Possible cause
Collective fault high pressure pump 1
Collective fault high pressure pump 2
Collective fault high pressure pump 3
Frost proteciton is active
Side brush has got hooked into the trailer
coupling
Loose connecting chord of the plates,
plates defective
Short circuit, water leakage
Loose connecting chord of the plates,
plates defective
Short circuit, water leakage
Emergency stop pressed, protective
switch triggered, reset button has not
been pressed
Night switch off of the unit is active, key
switch of the feed distributor is positioned
at "0"
Unit not in normal setting
Release signal by external control to sig-
nal distributor missing.
Unit not in normal setting
Drive-in door did not reach end position
Drive-out door did not reach end position
20
-
EN
Remedy
Switch on the protective motor switch
again, repeat washing process, call
Customer Service
Washing cannot be done until the
anti-frost temperature is exceeded
again
No action is required; washing will
continue automatically without the
back being washed a second time
Switch off and switch on the unit, re-
peat washing process, call Customer
Service
Press all emergency stops, check
that all protective motor switches
have been switched on, press reset
button in the control station
Check key switch of the feed distribu-
tor (position it to 1 or 2)
Drive unit to normal setting
Test the release signal; if there is no
external control: Install the wire jump-
er as per circuit diagram.
Drive unit to normal setting
Check door

Publicité