5-2. Setting Digital Meter Board PC4 DIP Switches

OM-1500-15 Page 20
1
2
3
.
Meter DIP switches are
factory set to display wirefeed
speed and voltage using 14 pin
feedback. Meter hold feature is
factory set to off position.
Wire Feed Speed Display
Inches Per Minute
S1
S2
S2
14 Pin
Voltage/Current
Voltage
Sense Kit
Feedback
(195194)
Meter Hold
(ON)
S1
Amps Display
S2
14 Pin
Current
Feedback
Meters Per Minute
S1
S2
S2
14 Pin
Voltage/Current
Voltage
Sense Kit
Feedback
(195194)
(OFF)
S1
S2
Voltage/Current
Sense Kit
(195194)
1
Front Meter Panel
2
S1 DIP Switch
3
S2 DIP Switch
If the DIP switches are set to a Meter
Hold (ON) position, the meter value
will hold 5 seconds after gun is trig-
gered. The meter value will continue
to hold for 8 seconds after trigger is
released or until gun is re-triggered.
.
When using power sources
without 14 pin voltage/current
feedback − optional remote
voltage/current kit 195194 is
required.
Indicates this DIP switch setting has
no effect on this function.
803 141/ Ref. 803 124