Labels & Symbols - Evolution FURYB1851 Instructions Originales

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Fury sPeciFicaTions
Machine sPeciFicaTions
Motor UK/EU (220-240V ~ 50Hz)
Motor USA (120V ~ 60Hz)
No Load Speed
Weight
cuTTing caPaciTies
Mild Steel Plate (Max Thickness)
Mild Steel Box Section (Max Wall Thickness)
)
Max Cutting Thickness (Wood 90
0
Max Cutting Thickness (Wood 45
0
)
BlaDe sPeciFicaTions
Diameter
Bore Diameter
Number of Teeth
Max Blade Speed
Thickness
noise & ViBraTion DaTa
Sound Pressure L
(Under Load)
PA
Sound Power Level L
(Under Load)
WA
Vibration Level (Under Load)
warning: Due to the power input of this product on start up, voltage drops may occur and
this can influence other equipment (e.g. dimming lights). So for technical reasons we advise,
if the mains-impedance is Zmax<0.431Ohm, these disturbances are not expected. If you require
further clarification, you may contact your local power supply authority.
4
www.evolutionpowertools.com
MeTric
iMPerial
1200W
5A
1200W
10A
3700min
3700rpm
-1
5.4kg
12lbs
MeTric
iMPerial
3mm
1/8"
3mm
1/8"
60mm
2-3/8"
40mm
1-1/2"
MeTric
iMPerial
185mm
7-1/4"
20mm
3/4"
16
16
3900min
3900rpm
-1
1.7mm
.067"
98,83dB(A) K=3dB(A)
109,83dB(A) K=3dB(A)
a h,W=3,78 m/s
a h,M=1,596 m/s
2
2
K=1,5 m/s
2
www.evolutionpowertools.com
(1.6) note: The vibration measurement
was made under standard conditions in
accordance with: EN60745-1.
The declared vibration total value has been
measured in accordance with a standard test
method and may be used for comparing one
tool with another.
The declared vibration total value may also be
used in a preliminary assessment of exposure.
(1.7)
ViBraTion
warning: When using this machine the
operator can be exposed to high levels of
vibration transmitted to the hand and arm.
It is possible that the operator could develop
"Vibration white finger disease" (Raynaud
syndrome). This condition can reduce the
sensitivity of the hand to temperature as
well as producing general numbness.
Prolonged or regular users of this machine
should monitor the condition of their hands
and fingers closely. If any of the symptoms
become evident, seek immediate
medical advice.
• The measurement and assessment of
human exposure to hand-transmitted
vibration in the workplace is given in:
BS EN ISO 5349-1:2001 and
BS EN ISO 5349-2:2002.
• Many factors can influence the actual
vibration level during operation e.g. the
work surfaces condition and orientation
and the type and condition of the machine
being used. Before each use, such factors
should be assessed, and where possible
appropriate working practices adopted.
Managing these factors can help reduce the
effects of vibration:
5
handling
• Handle the machine with care, allowing
the machine to do the work.
• Avoid using excessive physical effort on
any of the machines controls.
• Consider your security and stability,
and the orientation of the machine
during use.
work surface
• Consider the work surface material;
its condition, density, strength,
rigidity and orientation.
warning: The vibration emission during
actual use of the power tool can differ from
the declared total value depending on the
ways in which the tool is used.
The need to identify safety measures
and to protect the operator are based on
an estimation of exposure in the actual
conditions of use (taking account of all parts
of the operating cycle, such as the times the
tool is switched off, when it is running idle,
in addition to trigger time).
(1.8)
laBels & syMBols
warning: Do not operate this machine
if warning and/or instruction labels are
missing or damaged. Contact Evolution
Power Tools for replacement labels.
note: All or some of the following symbols
may appear in the manual or on the product.
EN
ES
FR

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Furyb1852Furyb1852euStealth1851Stealth1852Stealth1852eu

Table des Matières