The drawing is just an indication on the air intake
and not an example of installation.
6.4 ELECTRIC FAN APPLICATION AND
CONNECTIONS
6.4.1 Preparing the ducts
pull it until it is about 150 cm long.
While pulling the pipe, turn it from both ends in
opposite directions. (Fig. 6.4.1)
Cut the pipe with a knife or scissors at the required
length.

6.5 AIR FAN

The air fan (1) is located in the lower rear part of
the stove. (Fig. 6.5.1)
To access it, you will need to remove the door (2),
6.5.1 Connecting the fan
having sealed them with silicone.
Apply mortar between the pipes and the wall.
The air suction circuit to the fan must always be
perfectly sealed.
Failing this, when the fan is started, it will create a
strong vacuum which will draw back smoke from the
brazier grille with consequent exit of smoke through
the hot air outlets.

6.5.2 Installation of a room temperature probe

The installation of the probe must be effected on
air at 30 cm from the inlet of the convection fan.
For the installation follow the steps here below:
1)
drill a hole in the pipe;
2)
insert the probe shaft (2) into the pipe with the
washer (3) (Fig. 6.5.2);
3)
from inside the pipe insert the washer (4) and screw
the bolt (5) on the probe shaft (2);
probe shaft (2).
28
INSTALLATION
004775230 12/2016
Fig. 6.4.1
3
2
Fig. 6.5.1
6
2
1
Fig. 6.5.2
5
1
4
3