4/ INSTALLING YOUR WINE CABINET
Slightly tilt the cabinet backwards to adjust the front feet (adjusted by
screwing or unscrewing), so that you can level your cabinet (use of a
spirit level is recommended).
Install the carbon filter, which you will find inside your cabinet's
"accessories" packet, by placing it in the air circulation hole located
inside the cabinet on the top left hand side (see diagram below).
Fitting the handle (Full Glass door only on models 5059S-V3, 5059V-V3, 5259S-V3, 5259V-V3)
Unscrew the three screws placed on the side of the door, using the Allen
wrench, which you will find in the handle's box.
Position the handle on the specially designed groove on the door frame
(figure 2).
Insert the handle all the way into the groove using a forward movement
(figure 2).
Screw the three screws back on (figure 3).
Take care not to catch the seal when screwing.
Note: adjustment of the handle is possible thanks to the oblong holes.
Install the stop (which is located in the accessories bag) at the back of the
cabinet (see diagram).
This allows a space of 7 cm to be maintained between the wall and the
rear of the cabinet. This space allows your cabinet's power consumption
to be optimised.
Place the 2 caps in the 2 holes at the top of the cabinet.
Wall fixing of the cabinet
For large models, if the wine cabinet is not being built in, it is essential
to secure it to the wall to prevent it from tipping forward. You will find
all the necessary parts in the accessories bag supplied with the unit. For
installation (see diagram below):
1
A
Loosen the screws
.
2
B
Attach the bracket
to the cabinet with the screws
3
C
B
Clip the nut
to this bracket
(preferably choose the hole nearest
to the cabinet).
Warning: make sure that the part is correctly clipped by
pulling upwards by hand. The clip must not come out.
4
D
Preposition the wall bracket
(on the nut to determine the position
8
GB
for drilling the holes for the wall-mounting screws,
Never obstruct the front ventilation grid.
Beware: any changing of the control panel LED should only be
carried out by a qualified electrician.
Fig.1
View from above
Handle
Front
Figure 1
Fig.2
Figure 2
Fig.3
Do not push the caps all the way in,
in order to allow the rear stop to be
installed.
Slide the rear stop between the caps
and the wall of the cabinet, then push
the 2 caps all the way in.
5
Drill the holes then attach the wall bracket
E
.
Warning: ensure that the wall fixing can withstand a tensile
force of 100 kg.
A
.
6
G
F
Tighten screw
with the washer
there is contact between the wall bracket
Only full tightening of the screw will ensure correct fixing of the unit.
Repeat the installation on the other side of the cabinet.
1. Building in
Fig.1
A
Fig.2
Seal
Door frame
Fig.3
Dimensions for glass or full glass door:
A maxi
5059
832
5259
1792
Figure 3
5259 :
It is essential that the unit inside which the cabinet will be fitted
has an opening at the top, at the back, measuring at least 540mm in length
and 50mm in width (see technical door diagram).
D
with suitable screws
until it is screwed fully in and
D
C
and the nut
.
4/ INSTALLING YOUR WINE CABINET
G
F
C
D
A
B
E
B
C
D
A
B
C
D
x6
A mini
B
C mini
816
Glass door
549
821
Full glass
548
1776
Glass door
566
1781
Full glass
565
Hinge without pin
Flush fitting hinge
Pillar (model 5059 only)
No. 25 Torx screw
B
560 min.
C
594
600 min.
A
B
C
A
9
GB