OLM
OLM
OLM
OLM
OLM
OLM
OLM
OLM
OLM
OLM
Fig.8: Coupling of networks in existence
3. Assembly, startup procedure
and dismantling
3.1 UNPACKING, CHECKING
Check whether the package was deliver-
ed complete (see scope of delivery).
Check the individual parts for transport
damage.
Warning!
v
Use only undamaged parts!
3.2 ASSEMBLY
The equipment is delivered in a ready-to-
operate condition. The following procedure
is appropriate for assembly:
Check whether the switch pre-setting
suits your requirements (see chap. 1.5).
Pull the terminal block off the OSM and
wire up the supply voltage and indicator
lines.
Fit the OSM on a 35 mm standard bar to
DIN EN 50 022.
Suspend the upper snap-on slide bar of
the OSM in the standard bar and press it
down towards the standard bar until it locks
in position.
Fit the signal lines and if required the
control lines.
Notes:
– The housing of the OSM is grounded via
the standard bar. There is no separate gro-
und connection.
– Do not open the housing.
– The shielding ground of the industrial twi-
sted pair lines which can be connected is
electrically connected to the housing.
6
OLM
OLM
OLM
OLM
OSM
OLM
OLM
OLM
OLM
Fig. 9: Assambling the OSM
3.3 STARTUP PROCEDURE
You start up the OSM by connecting the
supply voltage via the 5-pin terminal block.
Lock the terminal block with the locking
screws at the side.
3.4 DISMANTLING
To dismantle the OSM from the stan-
dard bar, pull the OSM downwards and on
the bottom lift the OSM away from the
standard bar.
ELM
OSM
OLM
OSM
Fig. 10: Dismantling the OSM
4. Further support
In the event of technical queries, please talk
to your Siemens contact for industrial com-
munication in the offices responsible for
looking after you. You can find the addres-
ses
– in our IK10 catalogue
– and on the Internet
(http://www.ad.siemens.de/net).
Our hotline is also at your disposal:
Tel. +49 (911) 895-7000
Fax +49 (911) 895-7001