Proceed as follows if you wish to enable the function:
• Make sure you have enabled the extended Menu 3 (as shown by the
alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L3;
• Press the SET key;
• LED L3 becomes steady on and programming will be completed.
If you wish to enable the function at the power level set by the FORCE
trimmer, repeat the above mention programming, by pressing SELECT
twice (obtaining fast flashing of LED L3 instead of once) and then press
SET.
Repeat the procedure if you wish to restore the previous configuration.
8.4.4. LED L4 - SLAM LOCK: (in closing phase):
The control unit is supplied by factory with the Slam lock function disabled.
This function consists in adding, in the presence of a deceleration stage
during closing, a stroke lasting 1 second at the maximum power or at the
power selected with the "FORCE" trimmer, in such a way as to ensure
positive engagement of the gate lock, if installed. If you wish to enable the
Slam Lock function at maximum power, proceed as follows:
• Make sure you have enabled the extended Menu 3 (as shown by the
alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L4;
• LED L4 becomes steady on and programming will be completed.
If you wish to enable the function at the power level set by the FORCE
trimmer, repeat the above mention programming, by pressing SELECT
twice (obtaining fast flashing of LED L4 instead of once) and then press SET.
Repeat the procedure if you wish to restore the previous configuration.
8.4.5. LED L5 - ELECTRICK LOCK ACTIVATED BY DISABLED PED.
BUTTON:
The control unit is factory set with the function for electric lock activation
via the Pedestrian command disabled. The function for electric lock
activation with the Pedestrian command is used when, for example, the
application consists of a sliding gate with a pedestrian gate alongside.
With this function enabled the sliding gate can be opened both using
commands from the P/P Pushbutton and the remotes, and via the PED
commands from the pedestrian gate by activating the electric lock.
To enable this function proceed as follows:
• Make sure you have enabled the extended Menu 3 (as shown by the
alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L5;
• LED L5 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
8.4.6. LED L6 - FLASHING LIGHT / INDICATOR LIGHT / COURTESY
LIGHT:
By activating this function it is possible to change the indicator light (it does
not flash during the pause), while the flashing output becomes a courtesy
light. To enable this function proceed as follows:
• Make sure you have enabled the extended Menu 3 (as shown by the
alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L6;
• LED L6 becomes steady on and programming will be completed.
If you wish to enable the second variation, repeat the operation described
above, pressing the SELECT key twice (obtaining the fast flashing of the
LED L6 instead of once) and then press SET (the LED does not light up).
Repeat the procedure if you wish to restore the previous configuration.
Courtesy Light Operation: The 24 ~ 4W max. Courtesy Light output will
switch on for 3 minutes whenever an opening command is transmitted.
8.4.7. LED L7 - PRE-FLASH/FLASH IN PAUSE:
The control unit is supplied by the factory with the Pre-flashing and Flashing
during Pause (3 sec. pre-flash before closing phase) both disabled.
Pre-flashing operation: The 24V flasher output will always be
activated 3 seconds before the closing manoeuvre.
If you wish to enable the Preflashing function, proceed as follows:
• Make sure you have enabled the extended Menu 3 (as shown by the
alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L7;
• LED L7 becomes steady on and programming will be completed.
Flashing operation during the Pause: The 230 Vac and 24V flashing light
output will remain active if the pause time is previously programmed. If
you wish to enable this function, repeat the operation described above,
pressing the SELECT key twice (obtaining the fast flashing of the L7 LED)
42
COMUNELLO ®Copyright 2019 - All rights reserved
and then press SET. The L7 LED will remain on steady.
Repeat the procedure if you wish to restore the previous configuration.
9 RESET
If it is necessary to restore the control unit to the factory configuration,
press the SELECT and SET keys simultaneously for about 5 seconds;
this will cause all the RED indicator LEDs to light simultaneously followed
immediately by the control unit switching off.
10 DIAGNOSTICS
Photocell Test:
The control unit is prearranged for connection of safety devices in
compliance with standard EN 12453 point 5.1.1.6. At each operating
cycle a functional test of the connected photocell is performed. In the case
of an open circuit and/or malfunctioning of the photocell, the control unit
does not enable movement of the gate and visually signals the test failed
condition by causing all the indicator LEDs to blink simultaneously. As soon
as correct operation of the photocell is restored, the control unit is ready
for normal use. This operating mode guarantees failure mode monitoring in
compliance with EN 954-1 Category 2.
Commands input test:
In correspondence with each low voltage command input, the control unit
is equipped with an indicator LED so that the status of the input can be
checked at a glance.
Operating logic: LED on input closed, LED off input open.
Flashing of all the LEDs of the MAIN MENU:
• obstacle for current measurement;
• obstacle for encoders;
• radio control already programmed;
• non-compliance with the rule of the first stored remote control;
Black-out test:
After programming the motor time, simulate a Black-Out and check that
the leaves perform a complete opening maneuver and a complete closing
maneuver."
11 WARRANTY
Fratelli Comunello S.p.A. guarantees the proper functioning of the actuators
for 24 months from the date of manufacture, provided that the performance
specifications indicated in the product instruction manuals are complied
with. Fratelli Comunello S.p.a. guarantees exclusively, and therefore with
the exclusion of claims for compensation made by equivalence, the free
repair or replacement of defective parts that will be recognised as such,
according to the unquestionable technical judgement of the staff of Fratelli
Comunello S.p.A. The material under warranty shipped to the headquarters
of Fratelli Comunello S.p.A., must be shipped prepaid and will then be sent
back carriage forward. The material considered defective and shipped to
Fratelli Comunello S.p.A. will remain the property of the latter.
- The cost of labour required for repairs and replacements remains the
responsibility of the purchaser. No compensation is paid for the period of
inactivity of the plant.
The intervention does not extend the duration of the warranty. Under
penalty of forfeiture, the buyer must report any product defects and faults
within a term of 8 (eight) days to be calculated respectively from the date
of discovery of the defect or from the date of delivery of the goods. The
report must be made exclusively in writing. The warranty does not include:
Breakage or damage due to transportation; failure or damage caused by
faults in the electrical system present at the premises of the purchaser of
the product and/or by neglect, negligence, inadequacy, abnormal use of
the system; failure or damage due to tampering by unauthorised personnel
or consequent to incorrect use/installation (in this regard, we system
maintenance at least every six months is advised) or the use of non-original
spare parts; defects caused by chemical agents and/or atmospheric
phenomena.
The warranty does not include the cost for consumables or for alleged
defects or casual controls.
Product characteristics
"Product Features Fratelli Comunello S.p.A. products are subjected
to continue changes and improvements; their technical features
and
image
may
therefore
change
Competent court "
Since the contract of sale is confirmed by an Order Confirmation drawn up
in Rosà (Postal Code 36027 - ITALY), any such dispute shall be settled by
the laws of Italy and by the court of Vicenza (VI) ITALY.
without
previous
notice.