6 MENU DESCRIPTION AND PROGRAMMABLE FUNCTIONS
The control panel has a MAIN MENU and three sub-menus called EXTENDED MENUS to customize the programming and the various system functions.
Pressing the SELECT button several times in succession you can scroll through the menu displayed by the 7 LEDs to choose the desired function (flashing LED
correspondingly flashing) and change its functionality with the SET button (the LED becomes fixed with function enabled or, conversely, off with function disabled).
THE ""LEV"" LED STATUS INDICATES WHICH MENU IS ACTIVE"
Use the SELECT key by pressing it several times to select the desired function (the corresponding LED flashes) in the displayed menu and confirm with the SET key:
The first available menu is the MAIN menu summarized in Tab no. 2:
• Press the SELECT button and select the desired function from
MAIN MENU
the main menu
LIVEL 0 - MAIN MENU
LED
FUNCTION
DESCRIPTION
L1
STEP BY STEP
Selection of the opening logic
L2
CODE TX
Storage of remote controls
L3
CONDO
Activate the "Condominium"
function
L4
MOTOR TIME
Storage of the motor stroke with
slowdowns
L5
PAUSE TIME
Automatic closing setting
L6
DELAY
Adjustment of the delay between
the 2 leaves
L7
AUTO PROGRAM
Self-learning of the stroke with
slowdowns
Table 2
The second menu is the one defined as EXTENDED 1 and to access the programmable functions follow the instructions given in Tab. 3:
EXTENDED
• Press the SELECT button and scroll the LED menu until you
MENU 1
reach the LEV LED;
• Press SET once to access the EXTENDED menu 1.
LIVEL 1 - EXTENDED MENU 1
LED
FUNCTION
DESCRIPTION
L1
HOLD-TO-RUN
Hold-to-run input
L2
PEDESTRIAN /
Configuration of pushbuttons
SINGLE LEAF
inputs PP and PPED
PUSHBUTTON
L3
PEDESTRAIN
Configuration of the PPED input
BUTTON / DS3
as partial opening or as additional
photocell input
L4
PHOTOTEST
Perform the photocell test before
each movement
L5
DS2 STOP IN
Configuration of DS2 photocells
CLOSE
input
L6
DS1 PARTIAL
Configuration of DS1 photocells
INVERTION
input
L7
BLOCK / 8K2
Configuration of N.C. STOP or 8.2
K Ohm resistive input.
Table 3
34
COMUNELLO ®Copyright 2019 - All rights reserved
The LEV function LED stays on FIXED:
LED ON
Open-Stop-Close-Stop (it closes after the pause time in a partial
opening phase)
Memorised controls
After the first one, the other inputs are ignored during the opening and
the pause time
Stored stroke
Automatic closing period stored
4 sec. in OPEN, adjustable from 4 to max. 15 sec. in CLOSE
Memorized self-learning of the stroke
The LED of the LEV function FLASHES with this frequency
LED ON
Enabled function
N.O. PPED button acts like single leaf (performing the stored stroke of
MOT1)
OPEN and CLOSE by 2 different buttons:
PP: Open
PPED: Close
Configuration of N.O. PPED input as DS3
Enabled function
STOP in CLOSE once the contact is open, then reversal
Partial reversal in CLOSE
8.2 K Ohm resistive input configuration
LED OFF
DEFAULT
Automatic (Open-Close)
Empty storage
Disabled function
30 seconds, without slowdown
(default)
Not active
Leaf delay disabled
Disabled function
LED OFF
DEFAULT
Disabled function
Partial opening/pedestrain leaf
PP: Open / Close button
PPED: partial open of MOT1
Configuration of the PPED input
as N.O. Pedestrian input
Disabled function
Reversal in CLOSE
Complete reversal in CLOSE
N.C. STOP pushbutton