8.3.4. LED L4 - FOLLOW ME:
The control unit allows the "Follow me" function to be configured;
programmable only if a Pause Time has already been set, this function
reduces the Pause Time to 5 seconds after freeing the DS1 photocell,
meaning the gate re-closes 5 seconds after transit of the user.
Note: this function is programmable only if a Pause Time has
already been programmed.
Proceed as follows if you wish to enable the function:
• Make sure you have enabled the extended Menu 2 (as shown by the
alternate flashing 1 1 0 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L4;
• Press the SET key;
• LED L4 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
8.3.5 LED L5 - PEDESTRIAN TIME
Programming of the stroke of motor no.1:
The control unit is factory set with Pedestrian opening time (associated to
Motor no.1) of 10 seconds without any deceleration.
That time can be modified and decreased or increased up to 4 min. To
set a new pedestrian time programming must be carried out with the leaf
associated to Motor no.1 in closed position as follows:
• Make sure you have enabled the extended Menu 2 (as shown by the
alternate flashing 1 1 0 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L5;
• Press the SET key;
• Motor no.1 starts the opening phase;
• When the desired deceleration starting point is reached press the SET
key (the leaf continues its stroke at a decelerated speed);
• The L5 LED will start to flash more slowly and the Motor will decelerate;
• When the desired position is reached, press the SET button to end the
Opening cycle;
• The L5 LED will flash again normally and the motor will start Closing once
more;
Repeat the procedures described above for the Closing phase.
If you do not require the control unit to perform the deceleration, during
programming, when the opening and closing cycle has been completed
press the SET key twice consecutively rather than just once.
During programming, instead of the SET key on the control unit you can use
the button on the remote already stored.
8.3.6. LED L6 - AUXILIARY RADIO CHANNEL OPERATING LOGIC:
The control unit allows the operating logic of the Auxiliary Radio Channel
to be selected.
The control unit is factory set with "Monostable" operation of the
Auxiliary Radio Channel. If you wish to enable "Bistable" operation
proceed as follows:
• Make sure you have enabled the extended Menu 2 (as shown by the
alternate flashing 1 1 0 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L6;
• Press the SET key;
• LED L6 becomes steady on and programming will be completed.
If you wish to enable "3 Minutes Timed" operation, repeat the operation
described above; pressing the SELECT key twice (LED L6 will blink rapidly),
rather than once, and then pushing SET key. Repeat the procedure if you
wish to restore the initial configuration.
8.3.7. LED L7- REMOTE RADIO CONTROL PROGRAMMING:
The control unit allows the transmission code to be programmed remotely
without acting directly on the control unit SELECT key.
Remote programming of a Radio remote control is performed as follows:
• Send, continuously for a time in excess of 10 seconds, the code of a
previously saved remote control;
• the control unit thus enters programming mode as described in the main
menu (see sec. 9.1.2).
• If a previously saved pedestrian code is transmitted continuously the
control unit will enter programming mode of a new pedestrian code and
LED L2 will blink as though acquisition of the pedestrian code were
active (1 1 0 1 1 0 1 1 0);
• If the code is associated with the 2nd CH/AUX input the LED will blink
as though acquisition of the 2nd CH code were active (1 1 1 0 1 1 1 0
1 1 1 0).
To enable the remote programming function, proceed as follows:
• Make sure you have enabled the extended Menu 2 (as shown by the
alternate flashing 1 1 0 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L7;
• Press the SET key;
• LED L7 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the initial configuration.
8.4 EXTENDED MENU 3
The control unit is factory set to allow direct selection exclusively of the main
menu functions.
If you wish to enable the functions described in Extended Menu 3, proceed
as follows:
• Select blinking LEV LED;
• press SET 3 times;
• The led will start blinking (alternate flashing of the LEV LED
There will be 30 seconds to select the functions of the Extended Menu
3 using the SELECT and SET keys; once an additional 30 seconds have
elapsed the control unit reverts to the main menu.
ID
REFERENCE LED
L1
SOFT STOP
ON
L2
SOFT START
ON
L3
RELEASE STROKE
ON
L4
SLAM LOCK
ON
L5
ELS / CMD PED
ON
LAMP / L.CORT / INDICA-
L6
ON
TOR L
L7
PRELAMP / LAMP IN PAUSE
ON
LEV
LIVEL
8.4.1. LED L1 - SOFT STOP:
The control unit is supplied by the manufacturer with the Soft Stop function
disabled. To enable the function, proceed as follows:
• Make sure you have enabled the extended Menu 3 (as shown by the
alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L1;
• Press the SET key;
• LED L1 becomes steady on and programming will be completed.
In this way, the control unit will reduce the speed to zero gradually (within
2 seconds) at the end of the door stroke, when an intermediate STOP
command or a reverse command is sent.
Repeat the procedure if you wish to restore the previous configuration.
Notes:
- Soft-stop does not act when a limit-switch is intercepted, when the Stop
button/safety edge is activated and in the event of an obstacle.
8.4.2. LED L2 - SOFT START:
The control unit is supplied by factory with the Soft Start function disabled.
With this function enabled at the beginning of the movement the speed
gradually increase from the minimum to the value set by the "SPEED"
trimmer during the first 2 seconds of operation.
Proceed as follows if you wish to enable the function:
• Make sure you have enabled the extended Menu 3 (as shown by the
alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L2;
• LED L2 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
Important note: when the Soft Start function is enabled, the control unit
automatically disables the Starting Torque function, while if Soft Start is
disabled then Starting Torque is automatically enabled.
8.4.3. LED L3 - RELEASE STROKE (in opening phase):
The control unit is supplied by factory with the release stroke function
disabled. This function consists of sending a closing command for 2
seconds before starting the opening stroke: in this way the release of
the lock is facilitated to allow the correct execution of the opening phase.
COMUNELLO ®Copyright 2019 - All rights reserved
).
OFF
OFF
OFF
OFF
OFF
OFF
OFF
3 FLASHING
41