1 DESCRIPTION OF CONNECTIONS
Flashing light output
24VDC (max 25W)
Back-up
battery
Second.
Transf.
FUSE 1:
T15A 250V
CN4
CN5
CN8
FUSE 2:
T1,6A 250V
230Vca
Primary
Aliment.
Transf.
DIP SWITCH SW1
The SW1 Dip-Switches allow you to select the 1 or 2 motor function
and define which of the two motors starts first and which second.
SW1
SW1
SW1
ON
ON
ON
1
2
1
2
1
2
1
NON PRIS
2
RETARD
2
RETARD
MOTEUR
EN COMPTE
MOTEURS
MOT. 2
MOTEURS
MOT. 1
DIP SWITCH SW2
The SW2 Dip-Switches allow to change the direction of stroke
of each motor without physically intervening on the electrical
connections in the terminal block.
SW2
SW2
SW2
SW2
ON
ON
ON
ON
1
2
1
2
1
2
1
INV
INV
INV
INV
INV
INV
INV
OFF
OFF
MOT 1
OFF
OFF
MOT 2
MOT 1
MOT 2
CAUTION: DS1, DS2 and STOP/8K2 are bridged by the factory. To connect the photocells, the stop button and the edge sensors, it is
necessary to remove the jumper from the terminal.
TRIMMER SENS: It regulates the SENSITIVTY of motors
TRIMMER SPEED: It regulates the SPEED of motors
2
INV
TRIMMER SLOWING: It regulates the slowdown speed of motors
Encoder
Limit Switch M2
Motor 2
FCA-Open
FCC- Closed
Encoder
Motor 1
Limit Switch M1
FCA-Open
FCC- Closed
CN2
2nCH
N.A. output aux radio channel. (30V 1A)
2nCH
FOT+
24Vcc Power supply (5W)
FOT-
DS2
GND
DS1
S8K2
GND
PPED
PP
ELS+
ELS-
24V
GND
+LED
ANT-
ANT+
Schielding
Pole
Turning with a screwdriver towards the + increases the speed of the
motor stroke during the slowing down phase
Turning with a screwdriver towards the + increases the motor speed
during the stroke.
Turning with a screwdriver towards the + increases the sensitivity and
therefore the motor will block its stroke more quickly if an obstacle is
detected.
COMUNELLO ®Copyright 2019 - All rights reserved
N.C. Photocells
DS2 input
N.C. Photocells
DS1 input
STOP input/8K2
input for resistive
hedges
N.O. Step-by-step input
N.O. Pedestrian input
24Vcc Electric lock output
+ 24Vcc (max 5W)
GND
+ 24Vcc (max 4W) Indicator light
Antenna Cable
25