4.7. Ambiente
Temperatura de
De -30 a +70°C
funcionamiento
Almacenamiento
De -40 a +80°C
4.8. Dimensiones
L
180mm
B
170mm
K
160mm
J
150mm
H
40mm
D
6.5mm
Peso
760g
5.
TYPE TESTS
5.1. EMC - Emissions
Emission:
Test specifications
EN 55022
EN 55022
EN 61000-3-2
EN 61000-3-3
5.2. EMC - Immunity
Immunity:
Test specifications
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
(+)
Apparatus does not contain devices susceptible to magnetic fields
963857154_U
J
Reference standard EN 61000-6-3
Environmental Phenomena
Conducted disturbance
Radiated disturbance
Harmonic current emissions
Voltage fluctuations and flicker
Reference standard EN 61000-6-2
Environmental Phenomena
Electrostatic discharge
Radiated electromagnetic field
Electrical fast transients
Injected currents
Power frequency magnetic field
Dips/short interruptions
L
B
K
H
Result
Complies
Complies
Complies
Complies
Result
Complies
Complies
Complies
Complies
N.A. (+)
Complies
79