5.3. Climatic
Reference standard DNV No. 2.4 – 2006
Test specifications
Class: C (-25°C / +55°C)
Standard IEC 60068-2-2
Class: C (-25°C / +55°C)
Standard IEC 60068-2-2
Class: C (-25°C / +55°C / 100% R.H.)
Standard IEC 60068-2-30
5.4. Vibrations
Reference standard DNV No. 2.4 – 2006
Test specifications
Class: B
Standard IEC 60068-2-6
6.
ACCESSOIRES
Description
Fusibles
Ultra rapide, céramique, 10 A – 500 V
Potentiomètre externe
10 k - 2 W
COMPATIBILITE'
7.
MEC-20 M31FA600A
963857154_U
Environmental Phenomena
Dry Heat
Cold
Damp Heat
Environmental Phenomena
Vibration
Code
963823010
963824425
Power Factor
Regulator
M50FA400A
M40FA630A
✓
VARICOMP
M40FA632A
✓
✓
Result
Complies
Complies
Complies
Result
Complies
M40FA620A
M40FA621A
43